Verifying Proper Operation

WARNING
Make sure that power to the electrical outlet is turned
off at the circuit breaker panel or fuse box and that
the gas is turned off at the gas supply valve before
proceeding.
The cooktop must be properly grounded at all times
when electrical power is applied.
Prior to operating the cooktop, read the accompanying use
and care manual carefully.
1. Make sure all the cooktop burner controls are in the
OFF position.
2. Connect the power cord to the electrical outlet.
3. Turn on power to the electrical outlet at the circuit
breaker or fuse box.
4. Depress and turn one burner control knob at a time
slowly counterclockwise to the HIGH position. Verify
that the associated burner igniter sparks, then return
the knob to the OFF position. Repeat for all of the
remaining control knobs.
5. Turn on the gas supply valve.
6. Perform the following ignition test for all of the burners:
Press and turn the control knob slowly counter-
clockwise to the HIGH position. Only the selected
burner will spark. It may take up to four seconds
for the burner to ignite, at which time the igniter
will stop sparking. If ignition does not occur within
four seconds, turn off the knob, wait for at least five
minutes to allow any gas to dissipate, then repeat
the test.
Once the burner lights, rotate the control knob
counterclockwise from HIGH to LOW to adjust the
flame height progressively. On dual burners turn
the control knob to the simmer setting and make
sure the low level flame can be adjusted.
When the unit is installed properly, the flame will
be steady. It will also have a sharp, blue inner cone
that will vary in length proportional to the burner
size. The flame will be reduced by the Smart
Flame™ fea-
ture under the
grate fingers to
increase grate
life.
10
Installation Instructions
Normal Flame Appearance
NOTE: If the cooktop does not operate properly, follow
these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power plug is connected
to the electrical outlet and that power is turned on at
the circuit breaker or fuse box.
Check to make sure that the burners are properly
seated.
If the burner continues to spark after ignition without
stopping, have a licensed electrician check the electri-
cal outlet for proper grounding or reversed polarity.
Repeat the above burner ignition test.
If the appliance still does not work, contact Dacor
Distinctive Service at (877) 337-3226. Do not attempt
to repair the appliance yourself. If you need service, be
sure to have the model and serial numbers available
when you call. See inside cover for location.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
Burner normally
ON
lights when knob
reachs this
position
HIGH
position
Area of
operation
LOW
position
Dual Burner Control Knob
Burner normally
ON
lights when knob
reachs this
position
HIGH
position
Area of
operation
Single Burner Control Knob
Knob position
indicator
LOW
position
Area of
operation
HIGH
position
Knob position
indicator
LOW
position

Advertisement

Table of Contents
loading

This manual is also suitable for:

Renaissance rgc365

Table of Contents