Cabinet And Countertop Layout - Dacor SGM304 Installation Instructions Manual

Hide thumbs Also See for SGM304:
Table of Contents

Advertisement

Installation Specifications
Cabinet and Countertop Layout
WARNING
° . To-reduce the risk of personal injury caused by
reaching over.a hot appliance, avoid locating cabinet
storage space directly -above the cooktop.
«Failure to. meet or-exceed the maximum and. mini-
mum. dimensions/clearances stated in these. instruc-
tions may-result in a fire hazard.
° .
Follow the countertop manufacturer's instructions
regarding the minimum corner-radius, use of heat
reflective tape, reinforcement of corners, etc.
*
Carefully check the location where the cooktop will be
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
*
This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor raised vent system.
All tolerances +1/16" (+1.6 mm), -0
unless otherwise noted.
A
Combustible overhead
cabinets
13" max.?
(33.0 cm)
18" min.1*°
(45.7 cm)
Combustible
surface to rear
.
1 7/8" min.
See cutout
(4.8 cm)
dimensions
7 1/2" (19.1 cm) min. to
combustible side wall,
above counter both sides
' Measured from cooking surface (top of cooktop grate).
2 if installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
3 Not applicable for cabinets more than a horizontal distance of 6"
(15.2 cm) from edge of cooktop. Allow 7 1/2" (19.1 cm) from edge
of cutout.
Minimum Required Clearances Around the Cooktop
Model
A: Minimum
A: Recommended
SGM304
30" (76.2 cm)
36" (91.4 cm)
SGM365
36" (91.4 cm)
42" (106.7 cm)
SGM466
48" (121.9 cm)
54" (137.2 cm)
«
Allow a minimum
1/4" (6 mm) clearance between the
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed
below the cooktop.
ee
1/4" (6 mm)
min. clearance
to combustible
B
| surfaces
Under Cabinet Clearances
Model
B: Minimum*
SGM304
29" (73.7 cm)
SGM365
35 1/4" (89.5 cm)
SGM466
46" (116.8 cm)
* To allow clearance for hold down
brackets
*
The gas supply piping, gas shut-off valve and the elec-
trical outlet must be located so they do not interfere
with the cooktop when it is installed. If installing another
appliance in the cabinet below, allow for the routing of
gas and electrical service behind it.
The installation must allow for the following:
*
Access to the gas shut-off valve and regulator when
the unit is installed.
*
Access to the electrical outlet when the cooktop is in
place. The 40" (101.6 cm) power cord must be able to
reach the electrical outlet.
*
Access to the underside of the cooktop for service and
inspection purposes.
*
Clearance inside the cabinet to allow for proper hold
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed
shelf should not be installed below the cooktop. See the fo
lowing pages for countertop cutout dimensions.
Raised Vent Compatibility
if installing the cooktop with a raised vent, install only the
approved Dacor model numbers specified below:
Cooktop Modeis
Approved Raised Vent Models
SGM304
ERV30, PRV30 or RV30
SGM365
ERV36, PRV36 or RV36
SGM466
PRV46 or RV46
dacor.
§

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgm365Sgm466

Table of Contents