3. PRE-OPERATION INSPECTION

WARNING
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area. Be sure to
provide adequate ventilation
Operate the generator on a level surface. If the generator
is tilted, fuel spillage may result
Keep away from rotating parts while the generator is
running.
CAUTION
The generator is air-cooled and may be damaged if
ventilation is inadequate
1. Ensure the generator is on a level surface
2. Inspect engine oil:
CAUTION
gine oil is a major factor affecting engine performance
En
and service life. Non-detergent or vegetable oils are not
recommended.
CAUTION
Take out the oil filler cap and clean the dipstick.
Check the oil level by reinserting the oil filler cap without rotat-
Running the engine with insufficient oil can cause serious
ing it. Remove the oil filler cap and examine the oil level. If the
engine damage.
oil level is at or below the lower level, refill the oil to the upper
limit mark.
Reinsert the oil filler cap and tighten securely. (Refer to Fig.
3.0)