Advertisement

containing any of the harmful ingredients listed above are used prior to handling the device, such as hand sanitizer
that contain ethanolamine, hands must be completely dry before handling the device to prevent damage to the plastics.

Cleaning Materials Required

Alcohol wipes
Lens tissue
Cotton-tipped applicators
Isopropyl alcohol
Can of compressed air with a tube.
Cleaning Frequency
The cleaning frequency is up to the customer's discretion due to the varied environments in which the mobile devices
are used. They may be cleaned as frequently as required, but it is advisable to clean the camera window periodically
when used in dirty environments to ensure optimum performance.

Approved Cleanser Active Ingredients

100% of the active ingredients in any cleaner must consist of one or some combination of the following: isopropyl
alcohol, bleach/sodium hypochlorite, hydrogen peroxide or mild dish soap.

Harmful Ingredients

The following chemicals are known to damage the plastics on the device and should not come in contact with the
device: ammonia solutions, compounds of amines or ammonia; acetone; ketones; ethers; aromatic and chlorinated
hydrocarbons; acqueous or alcoholic alkaline solutions; ethanolamine; toluene; trichloroethylene; benzene; carbolic
acid and TB-lysoform.

Cleaning Instructions

Do not apply liquid directly to the device. Dampen a soft cloth or use pre-moistened wipes. Do not wrap the device in
the cloth or wipe, but gently wipe the unit. Be careful not to let liquid pool around the display window or other places.
Allow the unit to air dry before use.

Special Cleaning Notes

Many vinyl gloves contain phthalate additives, which are often not recommended for medical use and are known to
be harmful to the housing of the device. The device should not be handled while wearing vinyl gloves containing
phthalates, or before hands are washed to remove contaminant residue after gloves are removed. If products
containing any of the harmful ingredients listed above are used prior to handling the device, such as hand sanitizer
that contain ethanolamine, hands must be completely dry before handling the device to prevent damage to the plastics.
Cleaning Materials Required
Alcohol wipes
Lens tissue
Cotton-tipped applicators
Isopropyl alcohol
Can of compressed air with a tube.
Maintenance and Troubleshooting | 139
MN000116A02-A | May 2015