2.2.2 Water Supply

Customer
Recommendation:
Water supply line with stop valve and non-
return valve.
Connection to hot water line only with
suitable supply lines.
Supply system
Temperature:
Dynamic pressure: min. 0.8 bar at 6 l/min.
Static pressure:
CAUTION:
Check the drinking water quality before the installation especially when
installing a tank for manual filling.
A drinking water filter is recommended.
CAUTION:
When using new water pipes, flush them sufficiently before the installation.
Read local regulations carefully when choosing supply lines. Only use neutral
material with respect to taste.
07.2004
max. 75 °C (167 °F)
(11.6 PSI at 1.32 UK gal/min/
1.59 US gal/min)
max 10 bar (145 psi)
Installation / Putting into Operation
Dispenser
Connections for hoses:
R3/4''-3/8UNF USA/CAN
R3/4-R3/4 (Europe)
R3/4-R3/8 (The Netherlands)
USA: The dispenser must be installed with
an adequate return flow protection that
complies with local regulations.