Adjustments; Disassemblies; Disassembly Of The Front Part - Douwe Egberts Cafitesse 100 Service Manual

Table of Contents

Advertisement

Service Manual Cafitesse 100
G Housing
G.1 Adjustments
G.2 Disassemblies
G.2.1 Disassembly of the Front Part
Preparation:
Switch off the dispenser and disconnect the
mains supply.
Disconnect the dispenser from the water
supply.
Disassembly:
Remove the operating panel cover (1) with
the screw (2). (Fig. 1)
Remove the front cover and the advertising
panel towards the side.
CAUTION:
When the front cover is made
of glass, there is the danger of
being injured due to
unauthorized handling or
breakage of the glass.
Remove the cooling compartment lid (8).
(Fig. 1)
Remove the housing cover (9). (Fig. 1)
Remove the air chute (10). (Fig. 1)
Remove the rear wall (3). (Fig. 1)
Loosen the cables (4, 5, 6, 7) at the
control. (Fig. 1)
Remove the fan (11). (Fig. 1)
Remove the fan console (12). (Fig. 1)
Remove the metal air supply channel (13).
(Fig. 1)
Remove the shielding cover (14). (Fig. 1)
Withdraw the temperature sensor.
Remove the 2 screws (15). (Fig. 1)
Remove the tension rod (16), holding the
front part tightly. (Fig. 1)
Remove the 4 cable harnesses towards the
front.
Remove the outlet hose (17). (Fig. 1)
Hold the front part (18) with both hands
and and unhook it. (Fig. 1)
07.2004
8
2
1
11
12
13
xx
xx
x
x x
xx
x x
xx
x
x
S T
O P
14
Fig. 1
Functions - Housing
9
4
6
7
5
10
3
16
18
15
x x
x x
x
x x
x x
x x
x x
x
x
S T
O P
17
5G - 1