D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Mantels (Combustible/Non-Combustible)
1,3 cm
Thick Wall
Sheathing
Figure 5.3 Clearances To Combustible/Non-Combustible
Mantels Or Other Combustibles/Non-Combust-
ibles Above Appliance.
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
8 cm
MINIMUM
18 cm
Figure 5.4 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
20
30 cm
MAX.
MEASUREMENT
FROM TOP OF
36 cm
FIREPLACE
MIN.
OPENING
UNLIMITED
Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. N • 3/14
Figure 5.5 Front Side Finishing Detail
8,90 cm
2,5 cm
2,5 cm
AIR SPACE
Figure 5.6 Non-Combustible Zone
Note: AIR SPACE denoted in Figure 5.6 is defi ned by the
nailing tabs and metal standoffs.
Note: Factory installed non-combustible board may only
be replaced with HHT product code SUPERM-60 material
and must be fully replaced in its entirety.
2,5 cm
FRAMING
NAILING TAB
1,2 cm FACTORY-SUPPLIED
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE

Advertisement