Download Print this page

Viessmann Vitocal 222-G User Manual page 84

Advertisement

Vitocal 300-G/350-G
ID: 4605352_1304_03
Pos.
Designation
External heat source
wP
External heat source (oil/gas boiler) with Vitotronic 200, type KO1B, KO2B or KW6B
wQ
External EA1 extension for oil/gas boilers
wW
Mixer motor
wE
Flow temperature sensor VTS system
wR
High limit safety cut-out STB 70 °C
(for switching off secondary pump 6)
wT
High limit safety cut-out STB 70 °C
(for switching off external heat source wP)
wZ
Circulation pump for cylinder heating UPSB
wU
Boiler water temperature sensor KTS
(in the external heat source for connection to the heat pump)
wI
Contactor relay K1
wO
Contactor relay K2
DHW heating (cylinder loading system)
eP
Dual mode DHW cylinder
eQ
Cylinder temperature sensor STS top (for connection to heat pump control unit 4)
eW
DHW circulation pump ZP
eE
Motorised 2-way valve (N/C, on the DHW side)
eR
Flow limiter
eT
Plate heat exchanger Vitotrans 100
eZ
Cylinder loading pump SLP (on the DHW side)
DHW heating with solar backup
rP
Solar-Divicon, type PS10 with integral Vitosolic 100, type SD1 rQ
or
Solar-Divicon, type PS20 without control unit with separate Vitosolic, type SD1 rQ
rQ
Solar control unit Vitosolic 100, type SD1
rW
Collector temperature sensor KOL
rE
Solar collector
rR
Cylinder temperature sensor STS (for connecting to solar control unit rQ)
rT
High limit safety cut-out STB Solar (if required)
Heating water buffer cylinder
tP
Heating water buffer cylinder
tQ
Buffer temperature sensor PTS
Heating/cooling circuit with mixer M2
zP
Underfloor heating circuit/cooling circuit M2
zQ
Vitotrol 200A remote control
The following wireless accessories are available as an alternative to hardwired remote control
units:
oO
-Wireless base station
-Vitotrol 200 RF wireless remote control
-Wireless repeater
zE
Flow temperature sensor VTS M2
zR
Temperature limiter to restrict the maximum temperature of underfloor heating systems
zZ
Mixer motor (regulated by control unit 4)
zU
Heating circuit pump UP M2
qCP
Connection module with single room control, heating/cooling with pump logic
qCQ
Room thermostat (installation on finished walls), heating/cooling RTR-E 6726
qCW
Thermal actuator TS 5.11/230 (N/C, cores can be interchanged)
or
Thermal actuator TS+ 5.11/230 (N/C, cores can be interchanged)
Natural cooling function (NC)
uP
NC-Box with mixer
zI
3-way diverter valve
uQ
Primary cooling circuit pump
uW
Secondary cooling circuit pump
uE
Contact humidistat
uR
3-way mixer (KM BUS)
uT
2-way valve
Heating circuit without mixer A1
iP
Radiator heating circuit
iE
Heating circuit pump UP A1
Heating circuit with mixer M3
oP
Radiator heating circuit
oE
Flow temperature sensor VTS M3
oT
Mixer extension kit
oZ
Heating circuit pump UP M3
oU
Mixer motor M3
System examples
(cont.)
Part no.
See Viessmann pricelist
7452 091
See Viessmann pricelist
7170 965
on site
on site
See Viessmann pricelist
7170 965
7814 681
7814 681
See Viessmann pricelist
7170 965
on site
7180 573
on site
See Viessmann pricelist
7820 403
Z012 018
Z012 027
Z007 387
Standard delivery pos. 41
See Viessmann pricelist
Standard delivery pos. 41
Z001 889
See Viessmann pricelist
7170 965
See Vitoset pricelist
Z008 341
Z011 413
Z011 219
7456 538
7183 288
7151 728 or 7151 729
7450 657
on site
7247 845
7247 853
7373 722
7419 860
Z009 565
Standard delivery pos. 70
Standard delivery pos. 70
Standard delivery pos. 70
Standard delivery pos. 70
Standard delivery pos. 70
Standard delivery pos. 70
See Vitoset pricelist
on site
See Vitoset pricelist
Standard delivery pos. 95
7301 063 or 7301 062
on site
See Viessmann pricelist
VIESMANN