Vitocal 200-G
(cont.)
Equipment required
ID: 4605363_1304_03
Pos.
Designation
1
Vitocal 200-G heat pump, type BWC
2
Heat pump control unit Vitotronic 200, type WO1B
3
Outside temperature sensor ATS
4
Instantaneous heating water heater
6
Secondary pump
7
Circulation pump for cylinder heating UPSB
qW
Safety equipment block with safety assembly
qE
Expansion vessel, heating circuit
qR
High limit safety cut-out STB 70 °C (for stopping the circulation pump for cylinder heating)
qT
Primary pump
wP
Brine accessory pack
wQ
Pressure switch, brine circuit
wW
Brine distributor for geothermal probes/geothermal collectors
wU
Geothermal probe/geothermal collector
DHW heating
eP
DHW cylinder Vitocell 100-V, type CVW
3
eW
Cylinder temperature sensor STS
eU
DHW circulation pump ZP
DHW heating with a solar thermal system
eP
DHW cylinder Vitocell 100-V, type CVW
eQ
Cylinder temperature sensor in the solar return SOL
eW
Cylinder temperature sensor STS
eU
DHW circulation pump ZP
eO
Solar heat exchanger set for installation on the Vitocell 100-V, type CVW
rQ
High limit safety cut-out STB (if required)
rW
Solar-Divicon, type PS10 with integral Vitosolic 100, type SD1 rU
or
Solar-Divicon, type PS20 without control unit with separate Vitosolic, type SD1 rU
rE
Solar circuit pump R1
rR
Collector temperature sensor KOL
rT
Solar collector
rU
Vitosolic 100, type SD1
rO
Expansion vessel, solar circuit
Natural cooling function (NC)
iP
NC-Box with mixer
iQ
3-way diverter valve
iW
Secondary cooling circuit pump
iE
Contact humidistat
iR
Primary cooling circuit pump
iT
Mixing valve
iI
2-way valve
iO
Flow temperature sensor VTS
Heating/cooling circuit without mixer A1
oP
Underfloor heating circuit/cooling circuit A1
oQ
Vitotrol 200A remote control
The following wireless accessories are available as an alternative to hardwired remote control
units:
oO
– Wireless base station
– Vitotrol 200 RF wireless remote control
– Wireless outside temperature sensor
– Wireless repeater
oW
Overflow valve
oE
Temperature limiter to restrict the maximum temperature of underfloor heating systems (option-
al)
qCP
Connection module with single room control, heating/cooling with pump logic
qCQ
Room thermostat (installation on finished walls), heating/cooling RTR-E 6726
qCW
Thermal actuator TS 5.11/230 (N/C, cores can be interchanged)
or
Thermal actuator TS+ 5.11/230 (N/C, cores can be interchanged)
Accessories (optional)
8
KM BUS distributor (if there is more than one KM BUS subscriber)
oI
LON communication module
qXP
Vitocom 100 type GSM 2
qXQ
Vitocom 100 type LAN 1 with communication module
qXW
Vitocom 200 type LAN 2 with communication module
qXE
Vitocom 200 type GP 3 with communication module with SIM card
VIESMANN
64
Part no.
See Viessmann pricelist
Standard delivery pos. 1
Standard delivery pos. 2
Z009 562
Standard delivery pos. 1
Standard delivery pos. 1
Standard delivery pos. 1
See Vitoset pricelist
on site
Standard delivery pos. 1
See Viessmann pricelist
9532 663
See Viessmann pricelist
on site
Z002 885
7170 965
See Vitoset pricelist
Z002 885
Standard delivery pos. 47
7170 965
See Vitoset pricelist
7186 663
Z001 889
Z012 018
Z012 027
Standard delivery pos. 42
Standard delivery pos. 47
See Viessmann pricelist
Z007 387
See Vitoset pricelist
Z009 565
Standard delivery pos. 80
Standard delivery pos. 80
Standard delivery pos. 80
Standard delivery pos. 80
Standard delivery pos. 80
Standard delivery pos. 80
7183 288
See Vitoset pricelist
Z008 341
Z011 413
Z011 219
7455 213
7456 538
on site
7151 728 or 7151 729
7247 845
7247 853
7373 722
7419 860
7415 028
7172 173
Z011 396 / Z011 388
Z011 224
Z011 390
Z011 392
System examples

Advertisement