Vitocal 222-G/242-G/333-G/333-G NC/343-G
ID: 4605509_1304_01
Pos.
Designation
Heating/cooling circuit with mixer M3
q-P
Underfloor heating circuit/cooling circuit M3 with mixer, controlled via KM BUS
oQ
Vitotrol 200A remote control
oT
Vitotrol 300B remote control
q-E
Flow temperature sensor VTS
q-R
Temperature limiter to restrict the maximum temperature of underfloor heating systems
– Version with immersion sensor
or
– Version with contact sensor
q-T
Mixer extension kit
2
q-Z
Heating circuit pump
q-U
3-way mixer, heating circuit M3
q-U
Mixer motor for 3-way mixer
qCP
Connection module with single room control, heating/cooling with pump logic
qCQ
Room thermostat (installation on finished walls), heating/cooling RTR-E 6726
qCW
Thermal actuator TS 5.11/230 (N/C, cores can be interchanged)
or
Thermal actuator TS+ 5.11/230 (N/C, cores can be interchanged)
Accessories (optional)
8
KM BUS distributor (if there is more than one KM BUS subscriber)
zU
Radio clock receiver
oQ
Vitotrol 200A remote control
oT
Vitotrol 300B remote control
qXP
Vitocom 100, type GSM 2
qXQ
Vitocom 100, type LAN 1 with communication module
qXW
Vitocom 200, type LAN 2 with communication module
qXE
Vitocom 200, type GP 3 with communication module with SIM card
qXR
Vitocom 300, type LAN 3 with LON communication module
qXT
Vitocom 300, type GP 4 with LON communication module
VIESMANN
48
(cont.)
Part no.
See Vitoset pricelist
Z008 341
Z011 411
Standard delivery pos. q-T
7151 728
7151 729
7301 063 or 7301 062
See Viessmann pricelist
See Viessmann pricelist
Standard delivery pos. q-T or
7450 657
7247 845
7247 853
7373 722
7419 860
7415 028
7450 563
Z008 341
Z011 411
Z011 396 / Z011 388
Z011 224
Z011 390
Z011 392
Z011 399
Z011 400
System examples