Download Print this page

Viessmann Vitocal 222-G User Manual page 82

Advertisement

Vitocal 300-G/350-G
Required parameter settings
ID: 4605352_1304_03
Vitotronic 200, type WO1B
Parameter
7000
7B00
7B0D
7100
7101
7103
7104
7010
7111
7008
7A00
3003
ID: 4605352_1304_03
Vitosolic 100, type SD1
Parameter
ANL
"RPM"
ID: 4605352_1304_03
Vitotronic 200, type KO1B / KO2B / KW6B
Parameter
General
General
General
System examples
(cont.)
Value
Function
10
With heating circuit A1/HC1, M2/HC2, M3/HC3, DHW cylinder
1
Enable external heat source, oil/gas
1
Enable external heat source for DHW
2
Natural cooling NC-Box with mixer
2
Natural cooling via heating circuit M2
180
Min. flow temperature, cooling
50
Influence room temperature hook-up cooling circuit
1
External H1 extension (swimming pool heating)
4
Cooling curve slope
1
Swimming pool connected and heated
1
With Vitosolic 100, type SD1
1
Vitotrol 200A remote control activated for heating circuit M2/HC2
Value
Function
1
System version
"0"
Pump with electronic speed control (delivered condition)
"1"
Standard solar circuit pump without separate variable speed control - speed controlled by
pulse pack control
"2"
Pump with PWM input (Wilo)
"3"
Pump with PWM input (Grundfos)
Value
Function
3A : 3
Blocking of the external heat source
3b : 2
External demand
9b : 70
Set value for external demand
4
VIESMANN
87

Advertisement