Download Print this page

Viessmann Vitocal 222-G User Manual page 212

Advertisement

Vitocal 300-A/350-A
Equipment required
ID: 4605093_1304_05
Pos.
Designation
1
Heat pump Vitocal 300-A
2
Heat pump control unit Vitotronic, type WO1B
with electrical connecting cables
3
Outside temperature sensor ATS
4
Instantaneous heating water heater
5
– For type AWCI: 3-way diverter valve for "Central heating/DHW heating"
or
– For type AWO: Circulation pump for cylinder heating UPSB
6
Secondary pump
7
Flow temperature sensor (integral for type AWCI) VTS
qW
Safety equipment block with safety assembly
qE
Expansion vessel
qT
Flow switch
DHW heating
eP
Vitocell 100-V DHW cylinder, type CVW, 390 litres
eQ
Cylinder temperature sensor STS
eU
DHW circulation pump ZP
DHW heating with a solar thermal system
eW
Cylinder temperature sensor in the solar return STS
eE
High limit safety cut-out STB for stopping the circulation pump for cylinder heating
eO
Solar heat exchanger set for installation on the Vitocell 100-V, type CVW
rQ
High limit safety cut-out STB (if required)
rW
Solar-Divicon, type PS10 with integral Vitosolic 100, type SD1 rU
or
Solar-Divicon, type PS20 without control unit with separate Vitosolic 100, type SD1 rU
rE
Solar circuit pump R1
rR
Collector temperature sensor KOL
rT
Solar collector
rU
Vitosolic 100, type SD1
Heating water buffer cylinder
zP
Heating water buffer cylinder
zQ
Buffer temperature sensor PTS
zW
Flow temperature sensor system VTS
– As immersion temperature sensor
or
– As contact temperature sensor
Heating/cooling circuit with mixer M2
uP
Underfloor heating circuit/cooling circuit M2 with mixer controlled by the heat pump control unit
uQ
Vitotrol 200A remote control
The following wireless accessories are available as an alternative to hardwired remote control
units:
oO
-Wireless base station
-Vitotrol 200 RF wireless remote control
-Wireless repeater
uE
Flow temperature sensor heating circuit M2 VTS
uR
Temperature limiter to restrict the maximum temperature of underfloor heating systems
– Version with immersion temperature sensor
or
– Version with contact temperature sensor
uZ
Heating circuit pump M2
uU
3-way mixer, heating circuit M2
Mixer motor for 3-way mixer
qCP
Connection module with single room control, heating/cooling with pump logic
qCQ
Room thermostat (installation on finished walls), heating/cooling RTR-E 6726
qCW
Thermal actuator TS 5.11/230 (N/C, cores can be interchanged)
or
Thermal actuator TS+ 5.11/230 (N/C, cores can be interchanged)
Active cooling function AC
qI
Frost stat
iE
Contact humidistat 230 V
iU
3-way diverter valve "Heating/cooling" in the return
iI
3-way diverter valve "Heating/cooling" in the flow
System examples
(cont.)
Part no.
See Viessmann pricelist
Standard delivery pos. 1
See Viessmann pricelist
Standard delivery pos. 1
See Viessmann pricelist
Standard delivery pos. 1
See Viessmann pricelist
For AWCI: Standard delivery
For AWO: see pricelist
Standard delivery pos. 1
7143 779
See Vitoset pricelist
Standard delivery pos. 1
Z002 885
7170 965
See Vitoset pricelist
Standard delivery pos. 47
on site
7186 663
Z001 889
Z012 018
Z012 027
Standard delivery pos. 42
Standard delivery pos. 47
See Viessmann pricelist
Z007 387
See Viessmann pricelist
7170 965
7170 965
7426 133
See Vitoset pricelist
Z008 341
Z011 413
Z011 219
7456 538
7183 288
7151 728
7151 729
See Vitoset pricelist
See Viessmann pricelist
7450 657
7247 845
7247 853
7373 722
7419 860
7179 164
7452 646
7814 924