Download Print this page

Viessmann Vitocal 222-G User Manual page 111

Advertisement

Vitocal 300-G/350-G
Required parameter settings
ID: 4605357_1304_04
Parameter
7000
7B00
7B0D
5030
5130
ID: 4605357_1304_04
Vitotronic 200, type KO1B / KO2B / KW6B
Parameter
General
General
General
Hydraulic installation scheme ID: 4605357_1304_04
4
WW
37
--2/212.3--
52
-2/224.7-
32
38
-2/224.6-
30
35
36
KW
33 --2/224.6--
tQ
tZ
tU
Note: This scheme is a general example without shut-off valves or safety equipment. This does not replace the need for on-site engineering.
VIESMANN
116
(cont.)
Value
Function
6
With heating circuit A1/HC1, M2/HC2, DHW cylinder
1
Enable external heat source, oil/gas boiler
1
Enable external heat source for DHW heating
according to type plate
Rated heating output, heat pump stage 1
according to type plate
Rated heating output, heat pump stage 2
Value
Function
3A : 3
Blocking of the external heat source
3b : 2
External demand
9b : 70
Set value for external demand
54
3
53
50
34
20
21
22
tP
27
62
--2/F13--
10
6
-2/224.3--29-
-2/211.2--14-
7
--2/211.4--
16
12
25
5
-
-
9
1
17
--2/F3--
2
--8/145--
71
73
--2/F12--
74
70
--2/225.1--76--
M2
76
--
--74/20--
77
--2/225.2;3--
13
-2/224.3--10-
29
-2/211.2--6-
14
-2/222.4--51-
55
8
System examples
91
--8/145--
90
A1
96
61
60

Advertisement