Resetting the Factory Default System and Device Values

1.
In NetLinx Studio, access the Device Addressing dialog:
Right-click on any system device listed in the Workspace and select Device Addressing.

Select Diagnostics > Device Addressing from the Main menu.

2.
Click the Set Device/System to Factory Default button (FIG. 38):
Device Addressing dialog
FIG. 38
This resets both the system value and device addresses (for definable devices) to their factory default settings. The system
information (in the OnLine Tree tab of the Workspace window) refreshes and then displays the new information.
3.
Click Done to close the Device Addressing dialog.
4.
Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to reboot.
NOTE: The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only
LED to blink.
5.
Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.
6.
Click the OnLine Tree tab in the Workspace window to view the devices on the System.
7.
Right-click the associated System number (or anywhere within the tab itself) and select Refresh System. This establishes a
new connection to the specified System and populates the list with devices on that system.
8.
Use Ctrl+S to save these changes to your NetLinx Project.