Control Ports and Indicators
The following sub-sections describe each control port on the Massio ControlPads. Refer to Overview section on page 13 for the
component layout of the rear panels of each type of Massio ControlPad.
RS-232
The Massio ControlPads features up to two RS-232 300-115,200 baud connector ports so you can connect up to two serial devices
to the ControlPad. The MCP-106 features one RS-232 connector; the MCP-108 features two connectors. The serial connectors
comply with EIA-232-F signal levels. The RX line supports polling for RS-232 devices for statuses such as power status, input
status, and lamp hours, so that this information can be provided to RMS.
NOTE: Massio ControlPads do not support RS-422 or RS-485 communications to devices.
FIG. 5 displays the RS-232 ports on the MCP-108.
RS-232 Serial Ports (MCP-108)
FIG. 5
FIG. 6 displays the wiring for the RS-232 connector.
RX
TX
GND
External Device
RS-232 connector wiring
FIG. 6
RELAYS
You can connect up to two independent external relay devices to the Relay connectors on the ControlPad. The relay port is only
available on the MCP-108.
FIG. 7 displays the RELAYS connector.
RELAYS connector
FIG. 7
Each relay is isolated and normally open.
24 V
@ 1 A maximum
DC
28 V
@ 1 A maximum
AC
Instruction Manual - Massio ControlPads and Keypads
TX
RX
GND
ControlPad
Wiring and Device Connections
14