Smart Array Controller Mini-Sas Cable Option - HP ProLiant ML110 Gen9 User Manual

Hide thumbs Also See for ProLiant ML110 Gen9:
Table of Contents

Advertisement

Item
Description
Port 1 controller connection
1
Mini-SAS port 1 connection
2
Port 2 controller connection
3
Mini-SAS port 2 connection
4
Install the Host Bus Adapter. HP recommends installing the H240 Host Bus Adapter in slot 3 or slot 5.
9.
Install the system air baffle (on page 24).
10.
If removed, install the PCI air baffle
11.
Install the access panel (on page 19).
12.
Return the server to an upright position.
13.
Connect each power cord to the server.
14.
Connect each power cord to the power source.
15.
Power up the server (on page 18).
16.

Smart Array Controller Mini-SAS cable option

To install the component:
Power down the server (on page 18).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Place the server on its side.
3.
Remove the access panel (on page 18).
4.
If installed, remove the PCI air baffle (on page 22).
5.
Remove the system air baffle (on page 23).
6.
Disconnect the existing Mini-SAS cables from the drive backplane and the Mini-SAS connectors on the
7.
system board.
Connect one end of the cable to the Smart Array Controller, route the cable underneath the metal tabs,
8.
and then connect the other end to the drive backplane.
("Install the PCI air
baffle" on page 22).