HP proliant ML110 gen9 Maintenance And Service Manual

HP proliant ML110 gen9 Maintenance And Service Manual

Hide thumbs Also See for proliant ML110 gen9:
Table of Contents

Advertisement

HPE ProLiant ML110 Gen9 Server
Maintenance and Service Guide
Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware
components and software. This guide is for an experienced service technician. Hewlett Packard Enterprise assumes that you are qualified
in the servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 790389-003
June 2016
Edition: 3

Advertisement

Table of Contents
loading

Summary of Contents for HP proliant ML110 gen9

  • Page 1 HPE ProLiant ML110 Gen9 Server Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications and requirements for hardware components and software. This guide is for an experienced service technician. Hewlett Packard Enterprise assumes that you are qualified in the servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
  • Page 2 © Copyright 2015, 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    HPE ATX 550-W Power Supply (non-hot-plug) ...................... 61 RPS enablement kit ..............................62 HPE redundant power supply input module ......................64 Redundant power supply blank ..........................66 HP Trusted Platform Module ..........................67 Troubleshooting ............................68 Troubleshooting resources ............................. 68 Contents 3...
  • Page 4 Diagnostic tools ............................69 Product QuickSpecs ............................... 69 HPE iLO ................................. 69 Active Health System ..........................69 HPE ProLiant Pre-boot Health Summary ....................70 Integrated Management Log ........................70 HPE UEFI System Utilities ............................. 70 Using UEFI System Utilities ......................... 71 Embedded Diagnostics option ........................
  • Page 5: Customer Self Repair

    Customer self repair Hewlett Packard Enterprise products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period Hewlett Packard Enterprise (or Hewlett Packard Enterprise service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, Hewlett Packard Enterprise will ship that part directly to you for replacement.
  • Page 6 • Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à Hewlett Packard Enterprise de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. • Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation.
  • Page 7 NOTA: alcuni componenti Hewlett Packard Enterprise non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, Hewlett Packard Enterprise richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.
  • Page 8 Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien von Hewlett Packard Enterprise, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an Hewlett Packard Enterprise zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an Hewlett Packard Enterprise zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen.
  • Page 9 deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, Hewlett Packard Enterprise podrá cobrarle por el de sustitución.
  • Page 10 Enterprise u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt Hewlett Packard Enterprise alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest Hewlett Packard Enterprise zelf welke koerier/transportonderneming hiervoor wordt gebruikt. Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van Hewlett Packard Enterprise.
  • Page 11 Para obter mais informações sobre o programa de reparo feito pelo cliente da Hewlett Packard Enterprise, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da Hewlett Packard Enterprise (http://www.hpe.com/support/selfrepair). Serviço de garantia apenas para peças A garantia limitada da Hewlett Packard Enterprise pode incluir um serviço de garantia apenas para peças.
  • Page 12 Customer self repair 12...
  • Page 13 Customer self repair 13...
  • Page 14 Customer self repair 14...
  • Page 15: Illustrated Parts Catalog

    Illustrated parts catalog Mechanical components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Item Description Spare part number Customer self repair (on page 5) Redundant power supply blank 698883-001 Mandatory...
  • Page 16 Facultatif—Pièces pour lesquelles une réparation par le client est facultative. Ces pièces sont également conçues pour que le client puisse procéder lui-même aux réparations. Cependant, les frais supplémentaires engendrés par le remplacement de ces pièces par Hewlett Packard Enterprise dépendent du type de service de garantie désigné pour votre produit.
  • Page 17: System Components

    System components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Illustrated parts catalog 17...
  • Page 18 Item Description Spare part Customer self number repair (on page M.2 SSD single module enablement kit 797907-001 Optional a) M.2 SSD enablement board — — b) M.2 SSD module — — c) SATA cable* — — M.2 SSD dual module enablement kit 797908-001 Optional a) M.2 SSD enablement board...
  • Page 19 c) 16 GB, single-rank x4 PC4-2400T-R* 819411-001 Mandatory d) 16 GB, dual-rank x4 PC4-2400T-R* 846740-001 Mandatory e) 32 GB, dual-rank x4 PC4-2400T-R* 819412-001 Mandatory System battery 234556-001 Mandatory Processors (include alcohol pad and thermal — — compound)** Intel Xeon E5-2600 v3 processors a) 1.60-GHz Intel Xeon E5-2603 v3, 6C, 85 W 762441-001 Optional...
  • Page 20 b) 12G, 540 mm, Mini-SAS cable* — — c) 540 mm Mini-SAS Y cable* — — d) 300 mm SATA to Mini-SAS cable* — — Trusted Platform Module — a) TPM 1.2* 505836-001 b) TPM 2.0* 812119-001 *Not shown **All processors in this HPE ProLiant server must have the same cache size, speed, number of cores, and rated maximum power consumption.
  • Page 21 No—Algunos componentes de Hewlett Packard Enterprise no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, Hewlett Packard Enterprise pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No"...
  • Page 22: Removal And Replacement Procedures

    Removal and replacement procedures Required tools You need the following items for some procedures: • T-10/T-15 Torx screwdriver (included with the server) • HPE Insight Diagnostics software ("HPE Insight Diagnostics" on page 72) Safety considerations Before performing service procedures, review all the safety information. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts.
  • Page 23: Server Warnings And Cautions

    This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
  • Page 24: Power Down The Server

    • Remove the PCI air baffle (on page 25). • Remove the system air baffle (on page 26). Power down the server Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and programs. IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.
  • Page 25: Remove The Front Bezel

    Slide and remove the access panel from the server. Remove the front bezel Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on its side. Remove the access panel (on page 24).
  • Page 26: Remove The System Air Baffle

    Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on its side. Remove the access panel (on page 24). Remove the PCI air baffle. Remove the system air baffle Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source.
  • Page 27: Non-Hot-Plug Drive Cage

    Remove the system air baffle. Non-hot-plug drive cage CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. To remove the component: Back up all server data on the drive. Power down the server (on page 24).
  • Page 28: Non-Hot-Plug Drive

    Remove the non-hot-plug drive cage. To replace the component, reverse the removal procedure. Non-hot-plug drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. To remove the component: Back up all server data on the drive.
  • Page 29: Hot-Plug Drive Blanks

    Remove the non-hot-plug drive. To replace the component, reverse the removal procedure. Hot-plug drive blanks CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank. To remove the component: Remove the front bezel (on page 25).
  • Page 30: Hot-Plug Drive

    Hot-plug SFF drive blank To replace the SFF drive blank, while pressing the release latch, slide the component into the bay until it is fully seated. Hot-plug drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
  • Page 31 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server.
  • Page 32: 8-Bay Sff Hot-Plug Drive Cage

    Box 2 To replace the component, reverse the removal procedure. 8-bay SFF hot-plug drive cage WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To remove the component: Power down the server (on page 24).
  • Page 33: M.2 Ssd Enablement Kit

    Box 1 Box 2 To replace the component, reverse the removal procedure. M.2 SSD enablement kit M.2 SSD enablement option WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power input modules, and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any system installation.
  • Page 34 To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on its side. Remove the access panel (on page 24). If installed, remove the PCI air baffle (on page 25).
  • Page 35: M.2 Ssd Module

    M.2 SSD module WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives, power input modules, and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any system installation.
  • Page 36 Disconnect the power and SATA cable. Release cables from clip and metal tabs. Press the metal tab. Removal and replacement procedures 36...
  • Page 37: Fans

    Remove the optical drive and disconnect the cable from the rear of the drive. To replace the component, reverse the removal procedure. Fans System fan module (92 x 32 mm) To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source.
  • Page 38: Upgrade Fan Module (92 X 38 Mm)

    Remove the 92 × 32 mm system fan module. To replace the component, reverse the removal procedure. Upgrade fan module (92 x 38 mm) To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server.
  • Page 39: Pci Fan Module

    Remove the 92 × 38 mm system fan module. To replace the component, reverse the removal procedure. PCI fan module CAUTION: For proper cooling do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. To remove the component: Power down the server (on page 24).
  • Page 40: Gpu Supporting Holder

    Disconnect the fan power cable and remove the PCI fan. To replace the component, reverse the removal procedure. GPU supporting holder To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server.
  • Page 41: Fbwc Module

    Remove the GPU with the supporting holder from slot 1: Open the PCIe slot cover retainer. Loosen the captive screw of the supporting holder. Open the latch on the slot 1 and remove the GPU. Remove the supporting holder. To replace the component, reverse the removal procedure. FBWC module WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  • Page 42 CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source.
  • Page 43: Smart Storage Battery

    Remove the cache module. To replace the component, reverse the removal procedure. Smart Storage Battery WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any installation, removal, or replacement procedure.
  • Page 44: Dimms

    Disconnect the battery cable from the system board connector and remove the Smart Storage Battery. To replace the component, reverse the removal procedure. DIMMs Memory-processor compatibility information • Intel Xeon E5-2600 v3 processors supports: Single-rank and dual-rank PC4-2133 (DDR4-2133) RDIMMs operating at up to 2133 MT/s Dual-rank PC4-2133 (DDR4-2133) LRDIMMs operating at up to 2133 MT/s •...
  • Page 45: Heatsink

    Remove the access panel (on page 24). If installed, remove the PCI air baffle (on page 25). Remove the system air baffle (on page 26). Open the DIMM slot latches. Remove the DIMM. To replace the component, reverse the removal procedure. Heatsink To remove the component: Power down the server (on page 24).
  • Page 46 Remove the heatsink from the processor backplate. To replace the component: Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to evaporate before continuing. Remove the thermal interface protective cover from the heatsink. Install the heatsink: Position the heatsink on the processor backplate.
  • Page 47: Processor

    Finish the installation by completely tightening the screws in the same sequence. Install the system air baffle. If removed, install the PCI air baffle. Install the access panel. Return the server to an upright position. Connect each power cord to the server. Connect each power cord to the power source.
  • Page 48 Place the server on its side. Remove the access panel (on page 24). If installed, remove the PCI air baffle (on page 25). Remove the system air baffle (on page 26). Remove the heatsink: Loosen one pair of diagonally opposite screws halfway, and then loosen the other pair of screws. Completely loosen all screws in the same sequence.
  • Page 49 Remove the processor from the processor retaining bracket. To replace the component: Install the processor. Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
  • Page 50 Close the processor retaining bracket. When the processor is installed properly inside the processor retaining bracket, the processor retaining bracket clears the flange on the front of the socket. Press and hold the processor retaining bracket in place, and then close each processor locking lever.
  • Page 51: System Board

    Finish the installation by completely tightening the screws in the same sequence. Install the system air baffle. If removed, install the PCI air baffle. Install the access panel. Return the server to an upright position. Connect each power cord to the server. Connect each power cord to the power source.
  • Page 52 Remove the heatsink from the processor backplate. Open each of the processor locking levers in the order indicated, and then open the processor retaining bracket. CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board, do not touch the processor or the processor socket contacts.
  • Page 53 Remove the processor from the processor retaining bracket. CAUTION: To avoid damage to the system board: • Do not touch the processor socket contacts. • Always install the processor socket cover after removing the processor from the socket. • Do not tilt or slide the processor when lowering the processor into the socket. CAUTION: Removal of the processor or heatsink renders the thermal layer between the processor and heatsink useless.
  • Page 54 To replace the system board: Install the system board. Open each of the processor locking levers in the order indicated in the following illustration, and then open the processor retaining bracket. Removal and replacement procedures 54...
  • Page 55 Remove the clear processor socket cover. Retain the processor socket cover for future use. CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board, do not touch the processor or the processor socket contacts.
  • Page 56 Press and hold the processor retaining bracket in place, and then close each processor locking lever. Press only in the area indicated on the processor retaining bracket. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab. Allow the alcohol to evaporate before continuing.
  • Page 57 Finish the installation by completely tightening the screws in the same sequence. IMPORTANT: Install all components with the same configuration that was used on the failed system board. Install all components removed from the failed system board. Connect all cables disconnected from the failed system board. Install the system air baffle.
  • Page 58: System Battery

    System battery If the server no longer automatically displays the correct date and time, then replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years. WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack.
  • Page 59: Dedicated Ilo Port Management Module

    Dedicated iLO port management module To remove the component: Power down the server (on page 24). Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on its side. Remove the access panel (on page 24).
  • Page 60: Hpe Atx 350-W Power Supply (Non-Hot-Plug)

    The iLO 4 Configuration Utility screen appears. Select Network Options, and then press Enter. The Network Options screen appears. Set the Network Interface Adapter field to ON, and then press Enter. Press F10 to save your changes. A message prompt to confirm the iLO settings reset appears. Press Enter to reboot the iLO settings.
  • Page 61: Hpe Atx 550-W Power Supply (Non-Hot-Plug)

    Remove the non-hot-plug power supply. To replace the component, reverse the removal procedure. HPE ATX 550-W Power Supply (non-hot-plug) WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning any installation, removal, or replacement procedure.
  • Page 62: Rps Enablement Kit

    Remove the non-hot-plug power supply. To replace the component, reverse the removal procedure. RPS enablement kit WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 63 Release the power cord from the strain relief clip. Remove the strain relief clip from RPS and retain the clip for future clip. Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on a sturdy, level surface.
  • Page 64: Hpe Redundant Power Supply Input Module

    Remove the RPS backplane. Remove the RPS bracket from the bay. To replace the component, reverse the removal procedure. HPE redundant power supply input module WARNING: To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 65 WARNING: To reduce the risk of injury from electric shock hazards, do not open power supplies. Refer all maintenance, upgrades, and servicing to qualified personnel. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
  • Page 66: Redundant Power Supply Blank

    Remove all power: Disconnect each power cord from the power source. Disconnect each power cord from the server. Place the server on a sturdy, level surface. Remove the access panel (on page 24). If installed, remove the PCI air baffle (on page 25). Remove the system air baffle (on page 26).
  • Page 67: Hp Trusted Platform Module

    Remove the power supply blank. To replace the component, reverse the removal procedure. HP Trusted Platform Module The TPM is not a customer-removable part. CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.
  • Page 68: Troubleshooting

    Troubleshooting Troubleshooting resources The HPE ProLiant Gen9 Troubleshooting Guide, Volume I: Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on ProLiant servers and server blades. To view the guide, select a language: •...
  • Page 69: Diagnostic Tools

    Diagnostic tools Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs). HPE iLO iLO is a remote server management processor embedded on the system boards of HPE ProLiant and Synergy servers.
  • Page 70: Hpe Proliant Pre-Boot Health Summary

    The Active Health System, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components. The Agentless Management Service is available in the SPP, which can be downloaded from the Hewlett Packard Enterprise website (http://www.hpe.com/servers/spp/download).
  • Page 71: Using Uefi System Utilities

    • Selecting the primary boot controller • Configuring memory options • Selecting a language • Launching other pre-boot environments such as the Embedded UEFI Shell and Intelligent Provisioning For more information on the UEFI System Utilities, see the HPE UEFI System Utilities User Guide for HPE ProLiant Gen9 Servers on the Hewlett Packard Enterprise website (http://www.hpe.com/info/uefi/docs).
  • Page 72: Hpe Insight Diagnostics

    Press the Enter key to clear the warning. Enter the serial number and press the Enter key. Select Product ID. The following warning appears: Warning: The Product ID should ONLY be modified by qualified service personnel. This value should always match the Product ID located on the chassis.
  • Page 73: Usb Support

    USB support Hewlett Packard Enterprise servers support both USB 2.0 ports and USB 3.0 ports. Both types of ports support installing all types of USB devices (USB 1.0, USB 2.0, and USB 3.0), but may run at lower speeds in specific situations: •...
  • Page 74: Automatic Server Recovery

    • Supports online array capacity expansion, logical drive extension, assignment of online spares, and RAID or stripe size migration • Provides diagnostic and SmartSSD Wear Gauge functionality on the Diagnostics tab • For supported controllers, provides access to additional features. For more information about HPE SSA, see the Hewlett Packard Enterprise website (http://www.hpe.com/servers/ssa).
  • Page 75: Component Identification

    Component identification Front panel components Item Description Optical drive (optional) Box 2 Box 1 USB 3.0 connectors Component identification 75...
  • Page 76: Front Panel Leds And Buttons

    Front panel LEDs and buttons Item Description Status Power On/Standby button Solid green = System on and system power LED Flashing green (1 flash per second) = Performing power on sequence Solid amber = System in standby Off = No power present If the system power LED is off, verify the following conditions: •...
  • Page 77: Rear Panel Components

    Subsystem Front panel LED behavior 1 flash System board 2 flashes Processor 3 flashes Memory 4 flashes Riser board PCIe slots 5 flashes FlexibleLOM 6 flashes Removable HPE Flexible Smart Array controller/Smart SAS HBA controller 7 flashes System board PCIe slots 8 flashes Power backplane or storage backplane 9 flashes...
  • Page 78: Rear Panel Leds

    Item Description USB 3.0 connectors Video connector Rear panel LEDs Item Description Status Power supply LED Solid green = Normal Off = One or more of the following conditions exists: • Power is unavailable • Power supply failed • Power supply is in standby mode •...
  • Page 79: System Board Components

    System board components Item Description Fan connector 3 Fan connector 2 DIMM slots 24-pin power supply connector RPSU connector Processor 4-pin power supply connector Front I/O connector Fan connector 1 Mini-SAS connector 1 Front USB 3.0 connector SATA connector 2 (for M.2 SSD 2) Mini-SAS connector 2 SATA connector 1 (for M.2 SSD 1 or optical drive) Internal USB 3.0 connector...
  • Page 80: System Maintenance Switch

    Item Description System maintenance switch TPM connector NMI header Dedicated iLO port connector Slot 5 PCIe3 x8 (8, 4, 1) Slot 4 PCIe3 x4 (4, 1) microSD card slot Slot 3 PCIe3 x8 (8, 4, 1) Slot 2 PCIe3 x4 (4, 1) Slot 1 PCIe3 x16 (16, 8, 4, 1) System maintenance switch Position...
  • Page 81: Nmi Functionality

    Select System Configuration → BIOS/Platform Configuration (RBSU) → System Options → SATA Controller Options → Embedded SATA Configuration, and then press Enter. Select Enable SATA AHCI Support, and then press Enter. Press F10 to save the selection. Press Y to save the changes. The Change saved confirmation prompt appears.
  • Page 82: Fan Locations

    Fan locations Item Description Default system fan (92 x 32 mm) Upgrade system fan (92 x 38 mm) The option is required to replace the default system fan when a 140 W workstation processor or SAS SSD drives are installed. PCI fan The PCI fan is part of the PCI fan and baffle option.
  • Page 83 • Four-bay LFF non-hot-plug drive model • Four-bay LFF hot-plug drive model Component identification 83...
  • Page 84: Hot-Plug Drive Led Definitions

    • Eight-bay SFF hot-plug drive model Hot-plug drive LED definitions Item Status Definition Locate Solid blue The drive is being identified by a host application. Flashing blue The drive carrier firmware is being updated or requires an update. Activity ring Rotating green Drive activity No drive activity...
  • Page 85 Item Status Definition The drive is not configured by a RAID controller. The blue Locate LED is behind the release lever and is visible when illuminated. IMPORTANT: The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode. It cannot be enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled, drives connected to the system board Mini-SAS connectors operate in AHCI or Legacy mode.
  • Page 86: Cabling

    Cabling Cabling overview This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance. For information on cabling peripheral components, refer to the white paper on high-density deployment at the Hewlett Packard Enterprise website (http://www.hpe.com/info/servers). CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.
  • Page 87: 4-Bay Lff Hot-Plug Drive Cabling

    4-bay LFF hot-plug drive cabling • Box 1 drive backplane connected to the system board Item Description Drive power cable Mini-SAS cable • Box 2 drive backplane connected the system board Item Description Drive power cable Mini-SAS cable Cabling 87...
  • Page 88 • Box 1 and box 2 drive backplanes connected to an H240 adapter Item Description Box 2 drive power cable Box 1 drive power cable Mini-SAS cable to port 2 of the controller Mini-SAS cable to port 1of the controller •...
  • Page 89: 8-Bay Sff Hot-Plug Drive Cabling

    • Box 1 and box 2 drive backplane connected to a P840 controller Item Description Box 2 drive power cable Box 1 drive power cable Mini-SAS Y-cable to port 1 of the controller 8-bay SFF hot-plug drive cabling • Box 1 drive backplane connected to the system board Item Description Drive power cable...
  • Page 90 • Box 1 drive backplane connected to an H240 adapter Item Description Drive power cable Mini-SAS port 1 connection to port 1 controller Mini-SAS port 2 connection to port 2 controller • Box 2 drive backplane connected to an H240 adapter Item Description Drive power cable...
  • Page 91 • Box 1 drive backplane connected to a P440 controller Item Description Drive power cable Mini-SAS Y-cable to controller • Box 2 drive backplane connected to a P440 controller Item Description Drive power cable Mini-SAS Y-cable to controller Cabling 91...
  • Page 92 • Box 1 drive backplane connected to a P840 controller Item Description Drive power cable Mini-SAS Y-cable connection to port 1 controller • Box 2 drive backplane connected to a P840 controller Item Description Drive power cable Mini-SAS Y-cable connection to port 2 controller Cabling 92...
  • Page 93: M.2 Ssd Cabling

    M.2 SSD cabling Item Description M.2 SSD 2 SATA cable M.2 SSD 1 SATA cable FBWC module cabling The FBWC solution is a separately purchased option. This server only supports FBWC module installation when a Smart Array P-Series controller is installed. Depending on the controller option installed, the actual storage controller connectors might look different from what is shown in this section.
  • Page 94: Smart Storage Battery Cabling

    • FBWC module on a P840 controller Smart Storage Battery cabling Cabling 94...
  • Page 95: Optical Drive Cabling

    Optical drive cabling Item Description Power supply cable Drive power cable SATA cable GPU cabling Cabling 95...
  • Page 96: Fan Cabling

    Fan cabling • Default system fan (92 x 32 mm) • Optional system upgrade fan (92 x 38 mm) Cabling 96...
  • Page 97: Power Supply Cabling

    • PCI fan Power supply cabling HPE ATX 350 W power supply (non-hot-plug) Item Description 8-pin power supply cable to box 2 drive backplane and optical drive 8-pin power supply cable to box 1 drive backplane 4-pin power cable to system board 24-pin power supply cable Cabling 97...
  • Page 98: Hpe Atx 550 W Power Supply (Non-Hot-Plug)

    HPE ATX 550 W power supply (non-hot-plug) Item Description 8-pin power supply cable to box 2 drive backplane and optical drive 6-pin power cable to GPU 8-pin power supply cable to box 1 drive backplane 4-pin power cable to system board 24-pin power cable to system board HPE 750 W redundant power supply Item...
  • Page 99: Front I/O Cabling

    Item Description 6-pin power cable to GPU 4-pin power cable to system board RPS cable to system board 24-pin power cable to system board Front I/O cabling Front USB 3.0 cabling Cabling 99...
  • Page 100: Specifications

    Specifications Environmental specifications Specification Value — Temperature range* 10°C to 35°C (50°F to 95°F) Operating -30°C to 60°C (-22°F to 140°F) Nonoperating — Relative humidity (noncondensing) Minimum to be the higher (more moisture) of Operating -12°C (10.4°F) dew point or 8% relative humidity Maximum to be 24°C (75.2°F) dew point or 90% relative humidity...
  • Page 101: Power Supply Specifications

    Power supply specifications Depending on the installed options and/or the regional location where the server was purchased, the server is configured with one of the following power supplies: • ATX 350 W Power Supply (non-hot-plug) (776442-B21) • ATX 550 W Power Supply (non-hot-plug) (776444-B21) •...
  • Page 102: Acronyms And Abbreviations

    Acronyms and abbreviations Advanced Memory Protection application program interface ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers backplane Customer Self Repair file allocation table FBWC flash-backed write cache graphics processing unit host bus adapter HPE SIM HPE Systems Insight Manager Integrated Lights-Out Integrated Management Log large form factor...
  • Page 103 Lights-Out Management nonmaskable interrupt NVRAM nonvolatile memory Optical Disk Drive PCIe Peripheral Component Interconnect Express POST Power-On Self Test RBSU ROM-Based Setup Utility REST representational state transfer redundant power supply serial attached SCSI SATA serial ATA Secure Digital small form factor Systems Insight Manager Service Pack for ProLiant Acronyms and abbreviations 103...
  • Page 104 Trusted Platform Module UEFI Unified Extensible Firmware Interface unit identification universal serial bus Acronyms and abbreviations 104...
  • Page 105: Documentation Feedback

    Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document. For online help content, include the product name, product version, help edition, and publication date located on the legal notices page.
  • Page 106: Index

    Hewlett Packard Enterprise Technical Support 5 customer self repair (CSR) 5 hot-plug power supply 66 hot-plug power supply calculations 101 HP Trusted Platform Module option 67 dedicated iLO management module option 59 HPE iLO 69 diagnostic tools 69, 71, 72, 74...
  • Page 107 PCI fan 39 POST error messages 68 identifying components 75 power cabling 97 iLO (Integrated Lights-Out) 69, 70 power calculator 101 iLO 4 (Integrated Lights-Out 4) 69 power fault 76 iLO activity LED 78 Power On/Standby button 75, 76 iLO connector 75 power supplies 97, 98 iLO link LED 78 power supply cabling 97...
  • Page 108 system battery 58 system board battery 94 system board components 79 system configuration settings 80 system fan 37 system maintenance switch 80 technical support 5 temperature requirements 100 TPM (Trusted Platform Module) 67 TPM, connector 79 troubleshooting 68 troubleshooting resources 68, 69 troubleshooting, firmware upgrade utility 68 Trusted Platform Module (TPM) 67 UID (unit identification) 75, 76, 78...

Table of Contents