Advanced Entry Calibration (continued)
Step
Action
After all entries have been
made, press the
to back out of the menu and
17
then press the
to save the settings and
return to the Ready Mode.
Note: If the Advanced Entry Calibration fails, enter MEDIA SETTINGS / CALIBRATION /
ADVANCED ENTRY / SENSOR GAIN and lower the selected Gain Number by one.
Select the new Gain Number then save the changes and exit the menu. Retest
your media. If unsuccessful, repeat the procedure until a usable gain is
obtained.

5.3 Reset Methods

There are three reset methods, each with a different affectivity. Proceed according to the
desired result:

5.3.1 Soft Reset

To clear any temporary host settings, press and hold the CANCEL Key for approximately
four seconds.

5.3.2 Level One Reset

To return the factory default settings or (if saved) a Factory Setting File, turn OFF the
printer. Press and hold the PAUSE and CANCEL Keys while turning ON the printer and until
the SYSTEM RESET message flashes.
Note:
The same as selecting SET FACTORY DEFAULTS; see Section 4.2.5.

5.3.3 Level Two Reset

To return the firmware default settings and clear all parameters, turn OFF the printer. Press
and hold the PAUSE, FEED, and CANCEL Keys while turning ON the printer and until the
SYSTEM RESET message flashes.
Note:
Calibration is required; see Section 5.2.
70
Displayed Message
Key
SAVE CHANGES?
ENTER KEY = YES
Key
!
Comment
From READY, press the
FEED Key to advance to
the next label TOF.