Fujitsu MAA3182SC Oem Manual page 41

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

(4)
RPL (rotational position locking) Status Change
If one of the events below related to disk rotational synchronization occurs, the UNIT
ATTENTION condition is generated for all INITs.
• Spindle synchronized
When rotational synchronization, started by the specification in the MODE SELECT or
MODE SELECT EXTENDED command (Page 4: Drive parameter), is completed.
• Spindle not synchronized
When rotational synchronization was attempted by the specification in the MODE SELECT or
MODE SELECT EXTENDED command (Page 4: Drive parameter), failed to synchronize the
spindle, or if synchronization which had been completed already deviated for some reason.
1 - 24