Fujitsu MAA3182SC Oem Manual page 203

Intelligent disk drives
Hide thumbs Also See for MAA3182SC:
Table of Contents

Advertisement

If a value specifying a length (other than zero) that does not match the data format on the disk
media is specified in the "Transfer byte length" field in the CDB, that command is terminated
with a CHECK CONDITION status without data being transferred to the INIT. The sense data
at this time indicate the following contents and the INIT can determine the correct "Transfer
byte length" from their contents.
Sense Key
Sense Code/Sub-sense Code :
"VALID" Bit
"ILI" bit
Information Field : ("Transfer byte length in the CDB) – (Original "Transfer byte length")
Remark The calculation formula for the information field expresses 1 logical data block as n
physical sectors and n sub-sectors, and when negative, as a complement of 2.
Error recovery processing during execution of this command is performed in accordance with
the specifications in the MODE SELECT parameters (Page code 1:
Recovery Parameter, Page Code 21: Additional Error Recovery Parameter, but the AWRE
flag and DTE flag are not applied.
3 - 134
: 05 = ILLEGAL REQUEST
24-00 = Invalid field in CDB
: "1"
: "1"
C141-E039-01EN