ed at the same time as the fireplace cassette without suitable measures
having being taken.
It must be ensured that there is sufficient combustion air when multiple
fireplaces are operated in one room or connected rooms!
This fireplace cassette is designed for temporary burning of wood.
Permanent operation can also not be achieved due to the extraction of
combustion air and is not permitted!
The type plate is located on the right hand side of your fireplace cassette on
the convection air jacket. It contains technical data and information. The type
plate may not be removed because this confirms that the appliance has been
tested. It is required for the approval and the yearly inspection carried out by
the heating inspector/chimney sweep.
The fireplace cassette may only be assembled and installed by a specialist
company. The first use of the fireplace cassette must be carried out by an
expert from the fitting company. The owner / operator of the system is to be
provided with a certificate in which the proper installation and the correct
settings / functionality of all control and safety components are confirmed.
Only a moderate fire may be ignited during the first use of the fireplace
cassette. This will avoid any cracks occurring in the firebox lining (these areas
can still contain residual moisture before the first use of the fireplace
cassette). Gradually increase the heat output over about 3 to 5 changes until
it has reached around 30% above the nominal heat output (see 2.3 "Tech-
3.2
3.3

Burning wood

3.3.1 First use/commissioning

framework PAGE - 38 -

Type plate

Type plate