F-49
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could
affect the machine's electrical characteristics, or if any electrical components are repaired or replaced, the
machine must be retested.
Input volts/Phase/Hertz
208/3/60
230/3/60
380/3/60
416/3/60
460/3/60
550/3/60
575/3/60
200/3/50
220/3/50
230/3/50
380/3/50
400/3/50
415/3/50
440/3/50
500/3/50
550/3/50
Mode
CC Stick
CV MIG
Auxiliary Output (#31-#32)
Auxiliary Output (#41-#42)
MINIMUM ACCEPTABLE OUTPUT VOLTAGE - AT MAXIMUM OUTPUT SETTINGS
Mode
CC Stick
CV MIG
Auxiliary Output (#31-#32)
Auxiliary Output (#41-#42)
TROUBLESHOOTING AND REPAIR

RETEST AFTER REPAIR

INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
11.0
10.0
21.0
19.1
18.3
11.0
10.5
10.1
MAXIMUM OPEN CIRCUIT VOLTAGES
Input Hertz
Control Settings
Output Control at Maximum
Arc Force Control at
Minimum
Output Control at Maximum
DC-600
6.0
5.5
5.0
4.2.
4.0
9.6
8.4
7.7
60
60
60
60
N/A
N/A
Maximum Idle KW
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
Open Circuit Volts
66/70
44/47
122/128 VAC
44/48 VAC
Load
815 Amps @ 44.0 Volts (Min)
815 Amps @ 44.0 Volts (Min)
5 Amps @ 120/126 VAC (Min)
5 Amps #41/45 VAC (Min)
F-49