Retest After Repair - Lincoln Electric CITOLINE i250 Service Manual

Table of Contents

Advertisement

Should a machine under test be rejected for any reason requiring the removal of any mechanical part that
could affect the machine's electrical characteristics, or if any electrical components are repaired or replaced,
the machine must be retested.
Model
CITOLINE i250 400Vac/3ph/50Hz
CITOLINE i300 400Vac/3ph/50Hz
After the repair, the unit shall be tested accordingly to the norm EN60974-4
Arc welding equipment "In-service inspection and testing"

RETEST AFTER REPAIR

Machine input and output
CITOLINE i250 & i300
Input Voltage
Output current range GMAW - FCAW
50-250 Amps – CITOLINE i250
50-300 Amps – CITOLINE i300
Output current range SMAW
10-250 Amps – CITOLINE i250 & i300
Maximum Open Circuit Voltage U
! IMPORTANT !
Max. Input Current (A)
22,5 max
19,8 max
72 Vp
Rated Output in
GMAW
250A@35%
300A@35%
0 peak