Reconnect Procedure - Lincoln Electric SVM188-A Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

A-5

RECONNECT PROCEDURE

Multiple voltage machines are shipped connected to
the highest input voltage listed on the machine's rating
plate. Before installing the machine, check that the
Reconnect Panel in the Input Box Assembly is con-
nected for the proper voltage.
CAUTION
Failure to follow these instructions can cause
immediate failure of components within the
machine.
When powering welder from a generator be sure to
turn off welder first, before generator is shut down,
in order to prevent damage to the welder
------------------------------
CONNECTION FOR HIGHEST RATING PLATE VOLTAGE, 50 OR 60 HZ.
LINK
CRI
L3
W
LINES
L2
V
CONTACTOR
INPUT
L1
U
H1
GND
H3
H2
PILOT
TRANSF.
CONNECTION FOR LOWEST RATING PLATE VOLTAGE, 50 OR 60 HZ.
LINK
L3
CRI
W
LINES
L2
V
INPUT
CTOR
L1
U
H1
GND
H2
H3
PILOT
TRANSF.
FIGURE A.4-Reconnect Panel Board Positions for Dual Voltage Machines
INSTALLATION
To reconnect a multiple voltage machine to a different
voltage, remove input power and change the position
of the reconnect board on the Reconnect Panel.
Follow The Input Connection Diagram located on the
inside
of
These connection diagrams for the following codes are
listed below.
1. For Dual Voltage except 380/500-460/575, see
Figure A.4. (M15009)
2. For 220/380/460, see Figure A.5. (M15010)
3. For 380/500-460/575, see Figure A.6. (M15011)
4. For 460 and 440 Single Voltage, see Figure A.7.
(S17894)
5. For 230/460/575, see Figure A.8. (M15666)
6. For Voltages not listed, see the Input Connection
Diagram pasted on the inside of the Case
Back Input Access Door.
1. TURN OFF THE INPUT POWER USING THE DISCONNECT SWITCH AT THE FUSE BOX
2. DISCONNECT AND INSULATE THE H2 LEAD TERMINAL WITH TAPE TO PROVIDE AT
LEAST 600 VOLT INSULATION.
3. CONNECT L1, L2 & L3 INPUT SUPPLY LINES H1 AND H3 TRANSFORMER LEADS TO THE INPUT SIDE OF
THE CRI CONTACTOR AS SHOWN.
4. CONNECT TERMINAL MARKED
5. MOUNT THE LINKS IN THE POSITIONS SHOWN WITH THE PROVIDED HEX NUTS,
DOUBLE UP THE LINKS IN TWO OF THE POSITIONS TO SAVE THEM FOR FUTURE USE. SECURE THE
REMAINING HEX NUTS IN PLACE.
1. TURN OFF THE INPUT POWER USING THE DISCONNECT SWITCH AT THE FUSE BOX
2. DISCONNECT AND INSULATE THE H3 LEAD TERMINAL WITH TAPE TO PROVIDE AT
LEAST 600 VOLT INSULATION.
3. CONNECT L1, L2 & L3 INPUT SUPPLY LINES H1 AND H2 TRANSFORMER LEADS TO THE INPUT SIDE OF
THE CRI CONTACTOR AS SHOWN.
4. CONNECT TERMINAL MARKED
5. MOUNT THE LINKS IN THE POSITIONS SHOWN WITH THE PROVIDED HEX NUTS.
DC-600
Case
Back
Input
TO GROUND PER LOCAL AND NATIONAL ELECTRIC CODES.
TO GROUND PER LOCAL AND NATIONAL ELECTRIC CODES.
A-5
Access
Door.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-600

Table of Contents