Retest a machine:
If it is rejected under test for any reason that require you to remove any part which could affect the machine's
electrical characteristics.
If you repair or replace any electrical components:
NOTE: The machine's output terminals should be energized with no external
The fans should turn on when the machine's output terminals are energized and a minimum of 15
amps of current is being drawn from the output terminals. The fans should stay on for approximately
7 minutes after the load is removed from the output terminals.
TROUBLESHOOTING

RETEST AFTER REPAIR

IDLE AMPS
Input Volts
230 VAC
460 VAC
575 VAC
load on the machine
FAN AS NEEDED (F.A.N.)
V275-S
Idle Watts
150 Watts
150 Watts
150 Watts
F-69