F-47
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that could
affect the machine's electrical characteristics or if any electrical components are repaired or replaced, the
machine must be retested.
Input Volts/Hertz
208/3/60
230/3/60
460/3/60
575/3/60
Mode
Maximum
Normal Range
Auxiliary Output (#31 - #32)
Auxiliary Output (#41 - #42 (#32A))
Output Control Setting
Minimum
Maximum
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
11
10
OPEN CIRCUIT VOLTAGE
OUTPUT LOAD READINGS
Amps
40-50
410
IDEALARC CV-300
5
4
Open Circuit Volts
55 VDC
10-43 VDC
112/119 VAC
39/42 VAC
F-47
Maximum Idle Watts
1000 watts
1000 watts
1000 watts
1000 watts
Volts
1-7 VDC
36 VDC Minimum