A-9
AUXILIARY POWER AND
CONTROL CONNECTIONS
Located at the left side of the front of the welder behind
a hinged cover is a 115VAC duplex receptacle for aux-
iliary power (60 Hertz Models only). On the right side of
the case front is a 14 Pin MS type receptacle for con-
nection of auxiliary equipment such as wire feeders.
Also, terminal strips with 115VAC and connections for
auxiliary equipment are located behind the hinged
access panel on the right side of the case front. (see
Auxiliary Power Table for details)
AUXILIARY POWER TABLE
Voltage and Circuit Breaker Ratings at Auxiliary Power
Connections for Various Models
Auxiliary
Power
Models
Connections
At Duplex
115V 15A
Receptacle
Terminal strip
115V 15A
terminals 31 & 32
MS-Receptacle
115V 15A
pins A & J
MS-Receptacle
42V 10A
pins I & K
115VAC
DUPLEX
RECEPTACLE
MODELS ONLY)
The 115VAC duplex receptacle is protected by a circuit
breaker located on the nameplate. The receptacle is a
NEMA 5-15R.
14 PIN MS TYPE RECEPTACLE
(For MS3106A-20-27PX Plug. L.E.C. Part #S12020-32)
Refer to the figure A.10 for the available circuits in the
14 pin receptacle.
42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.
115 VAC is available at receptacle pins A and J (All
Models). A 15 amp circuit breaker protects this circuit.
Note that the 42 VAC and 115 VAC circuits are electri-
cally isolated from each other.
FIGURE A.10 FRONT VIEW OF 14-PIN
CONNECTOR RECEPTACLE
K = 4 2
A = 3 2
B = G N D
L
C = 2
D = 4
E = 7 7
M
INSTALLATION
60 Hz
50/60 Hz
Models
No Duplex
115V 15A
115V 15A
42V 10A
(60
HERTZ
J = 3 1
I = 4 1
N
H = 2 1
G = 7 5
F = 7 6
PIN
LEAD NO.
A
32
B
GND
C
2
D
4
E
77
F
76
G
75
H
21
I
41
J
31
K
42
L
---
M
---
N
---
TERMINAL STRIPS
Terminal strips are available behind the cover on the
case front to connect wire feeder control cables that do
not have a 14 Pin MS-type connector. These terminals
supply the connections as shown in the following
Terminal Strip charts. NOTE: There are two work sense
lead connection points on the terminal strip. Connect
both the work sense lead #21 from the 14 pin connec-
tor and #21 lead of the control cable to "-21" when
welding positive polarity or to "+21" when welding neg-
ative polarity.
TERMINAL STRIP 1 (T.S.1)
Lead No.
75
76
77
TERMINAL STRIP 2 (T.S.2)
Lead No.
+21
Work Connection (Electrode Negative)
-21
Work Connection (Electrode Positive)
41
4
2
31
32
1.
115VAC circuit is on all models.
2.
As shipped from the factory Lead #21 from the 14 Pin connector is
connected
to
"-21"
This is the configuration for positive welding. If welding negative
polarity, connect lead #21 to the "+21" connection point on the ter-
minal strip (T.S.2).
DC-600
FUNCTION
115 VAC
Chassis Connection
Trigger Circuit
Trigger Circuit
Output Control
Output Control
Output Control
Work Sense Connection
42 VAC
1.
115 VAC
42 VAC
---
---
---
Function
Output Control
Output Control
Output Control
Function
42 VAC
Trigger Circuit
Trigger Circuit
115 VAC
1
115 VAC
1
on
the
terminal
strip
(T.S.2).
A-9