F-40
Should a machine under test be rejected for any reason requiring the removal of any mechanical part that
could affect the machine's electrical characteristics, or if any electrical components are repaired or replaced,
the machine must be retested.
TM
INVERTEC
CV350-R
TM
INVERTEC
CV350-R
TM
INVERTEC
CV350-R
Troubleshooting and Repair

RETEST AFTER REPAIR

INPUT – THREE PHASE ONLY
Standard Voltage/Phase/Frequency
380V ~ 415V(±10%)/3/50 or 60 Hz
RATED OUTPUT – DC ONLY
Duty Cycle
60%
100%
OUTPUT
Welding Current Range
60A ~ 350A
INVERTEC
Input Power at Rated Output
14kVA @ 60% Duty Cycle
Amperes
350A
270A
Open Circuit Voltage
67V
TM
CV350-R
F-40
Volts at Rated Amperes
31.5V
27.5V
Welding Voltage Range
17 V ~ 31.5V