C-4
12. Connect stick or air/carbon arc electrode and work
cable. See Figure C.2.
• Insert the electrode and work cables through the
strain relief loop on the right side (facing the front
of the machine) of the DC-600.
• Connect the electrode cable to the "Positive" ter-
minal on the right side of the MULTI-PROCESS
SWITCH.
• Connect the work cable to the "Negative" terminal
on the right side of the MULTI-PROCESS
SWITCH.
NOTE: The instructions above are for connecting
the stick polarity positive. To change the polarity,
turn the DC-600 OFF, and reverse the cables.
NOTE: When it is not necessary to have separate
ground cables for stick and semi-automatic or
automatic welding, connect a jumper from the
MULTI-PROCESS SWITCH "Work" terminal to the
MULTI-PROCESS SWITCH "negative" terminal.
See Figure C.2.
To operate the MULTI-PROCESS SWITCH, refer to the
operating instructions on the switch nameplate.
ACCESSORIES
CONNECTIONS FOR SEMI-AUTO-
MATIC OR AUTOMATIC WIRE FEED-
ER CONTROL
1. Set the DC-600 ON/OFF switch to OFF.
2. Set the DC-600 LOCAL/REMOTE switch to
REMOTE.
3. Set the DC-600 OUTPUT TERMINALS switch to
REMOTE.
4. Set the DC-600 MODE switch to the welding
process being used.
5. Refer to the proper connection diagram in the DIA-
GRAMS section for more information.
DC-600
C-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-600

Table of Contents