Toro Groundsmaster 4700-D Service Manual page 91

Hide thumbs Also See for Groundsmaster 4700-D:
Table of Contents

Advertisement

NOTE: Gear pump P1 supplies hydraulic flow to cutting
decks 5, 3 and 2 (also deck 7 on the GM 4700--D). Gear
pump P2 supplies flow to cutting decks 1 and 4 (also
deck 6 on the GM 4700--D).
Procedure for Gear Pump P1 and P2 Flow Test
NOTE: Over a period of time, the gears and wear plates
in the gear pump can wear. A worn pump will by pass oil
and make the pump less efficient. Eventually, enough oil
loss will occur to cause the cutting deck motors to stall
under heavy cutting conditions. Continued operation
with a worn, inefficient pump can generate excessive
heat and cause damage to the seals and other compo-
nents in the hydraulic system.
1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for approximately ten
(10) minutes. Make sure the hydraulic tank is full.
2. Park machine on a level surface with the cutting
decks lowered and off. Make sure engine is off and the
parking brake is engaged.
3. Raise hood to allow access to pump assembly.
CAUTION
Prevent personal injury and/or damage to equip-
ment. Read all WARNINGS, CAUTIONS and Pre-
cautions for Hydraulic Testing at the beginning
of this section.
4. Locate gear pump section to be tested (P1 or P2).
Thoroughly clean junction of appropriate hydraulic hose
and gear pump fitting. Disconnect hydraulic hose from
hydraulic fitting in gear pump (Fig. 48).
IMPORTANT: Make sure that the oil flow indicator
arrow on the tester is showing that the oil will flow
from the gear pump fitting, through the tester and
into the disconnected hose.
5. Install tester with pressure gauge and flow meter in
series with the disconnected hose and fitting in gear
pump section. Make sure the flow control valve on
the tester is fully open.
6. After installing tester, start engine and run at idle
speed. Check for hydraulic leakage and correct before
proceeding with test.
7. Start engine and move throttle to full speed (2870
RPM). Do not engage the cutting decks.
Groundsmaster 4500--D/4700--D
IMPORTANT: Do not fully restrict oil flow through
tester. In this test, the flow tester is positioned be-
fore the circuit relief valve. Pump damage can occur
if the oil flow is fully restricted.
8. Watch tester pressure gauge carefully while slowly
closing the flow control valve on tester until 2000 PSI
(138 bar) is obtained. Verify with a phototac that the en-
gine speed is 2870 RPM.
9. For a pump in good condition, flow indication should
be approximately 11.5 GPM (43.5 LPM).
10.Fully open flow control valve on tester and then shut
engine off. Record test results.
11. If measured flow is less than 9.6 GPM (36.3 LPM)
or a pressure of 2000 PSI (138 bar) cannot be obtained,
check for restriction in the pump intake line (including oil
filter and oil cooler). If line is not restricted, remove gear
pump and repair or replace as necessary.
12.After testing is complete, disconnect tester from hy-
draulic hose and fitting. Connect hose to the gear pump
fitting.
13.Repeat test for second pump section if required.
14.Lower and secure hood after testing is completed.
RIGHT
FRONT
1
1. Gear pump
2. Pump section P1 hose
Page 4 - - 57
2
Figure 48
3. Pump section P2 hose
Hydraulic System
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4500-d3085730858

Table of Contents