Toro Groundsmaster 4700-D Service Manual page 145

Hide thumbs Also See for Groundsmaster 4700-D:
Table of Contents

Advertisement

5. Remove four (4) cap screws and washers used to se-
cure fan (item 13) to fan hub. Remove fan.
IMPORTANT: Make sure to not damage the radiator
or other machine components while loosening and
removing the fan motor and bracket assembly.
6. Remove cooling fan motor and bracket assembly.
A. To prevent contamination of hydraulic system,
thoroughly clean exterior of fan motor and fittings.
B. Disconnect hydraulic hoses from fan motor. Put
caps or plugs on fittings and hoses to prevent con-
tamination. Label hydraulic lines for proper assemb-
ly.
C. Remove six (6) cap screws and flange nuts that
secure fan motor bracket to radiator.
D. Carefully remove fan motor and bracket assem-
bly from machine and place on suitable work sur-
face.
7. Remove hex nut (item 9) and washer (item 8) that se-
cure fan hub to fan motor. Use suitable puller to carefully
remove fan hub from fan motor shaft. Locate and re-
trieve woodruff key.
8. Remove two (2) cap screws (item 20), flat washers
(item 21) and lock nuts (item 14) that secure fan motor
to fan motor bracket. Remove fan motor from bracket.
9. If hydraulic fittings are to be removed from fan motor,
mark fitting orientation to allow correct assembly. Re-
move fittings from motor and discard O--rings.
Installation (Fig. 91)
1. If fittings were removed from fan motor, lubricate and
place new O--rings onto fittings. Install fittings into port
openings using marks made during the removal process
to properly orientate fittings. Tighten fittings (see Hy-
draulic Fitting Installation in the General Information
section of this chapter).
2. Position fan motor to fan motor bracket and secure
with cap screws (item 20), flat washers (item 21) and
lock nuts (item 14).
3. Thoroughly clean tapered surfaces of fan motor
shaft and fan hub. Place woodruff key in slot in motor
shaft.
Groundsmaster 4500--D/4700--D
4. Position fan hub onto motor shaft and secure with
washer (item 8) and hex nut (item 9). Torque nut from 27
to 33 ft- -lb (37 to 44 N- -m).
IMPORTANT: Make sure to not damage the radiator
or other machine components while installing the
fan motor and bracket assembly.
5. Carefully position fan motor and bracket assembly to
radiator and secure with six (6) cap screws and flange
nuts.
6. Remove caps and plugs placed in hoses and fittings
during removal to prevent contamination. Connect hy-
draulic hoses to cooling fan motor (see Hydraulic Hose
and Tube Installation in the General Information section
of this chapter).
7. Position fan to fan hub and secure with four (4) cap
screws and washers.
8. Install upper radiator shroud and air cleaner hose
(Fig. 92). Make sure that clearance between shroud and
cooling fan is at least 0.180" (4.6 mm) at all points.
9. Lower and secure hood.
5
2
3
4
6
1. Radiator
2. Upper radiator shroud
3. Screw (4 used)
4. Flange nut (4 used)
Page 4 - - 111
7
Figure 92
5. Air cleaner hose
6. Screw
7. Flat washer