Toro Groundsmaster 4700-D Service Manual page 156

Hide thumbs Also See for Groundsmaster 4700-D:
Table of Contents

Advertisement

Lift Control Manifold Service (GM 4700- -D)
20 ft- -lb
(27.1 N- -m)
5 ft- -lb
(6.8 N- -m)
25 ft- -lb
(33.9 N- -m)
11
12
11
5 ft- -lb
(6.8 N- -m)
1. Manifold body
2. Nut
3. Zero leak plug (#4)
4. Relief valve (port R1)
NOTE: The ports on the manifold are marked for easy
identification of components (e.g. P is the gear pump
connection port and R1 is the relief valve port). See Hy-
draulic Schematics in Chapter 9 -- Foldout Drawings to
identify the function of the hydraulic lines and cartridge
valves at each port location.
Hydraulic System
5 ft- -lb
(6.8 N- -m)
11
10
2
8
10
12
6
10
12
(27.1 N- -m)
Figure 101
5. Proportional relief valve (port TS)
6. Solenoid valve (ports S2, S3, S7, S8)
7. Solenoid valve (port S1)
8. Solenoid valve (ports S4, S6, S9)
Page 4 - - 122
20 ft- -lb
(27.1 N- -m)
4
7
5
10
12
11
9
5 ft- -lb
(6.8 N- -m)
20 ft- -lb
NOTE: The lift control manifold uses several zero leak
plugs. These plugs have a tapered sealing surface on
the plug head that is designed to resist vibration induced
plug loosening. The zero leak plugs also have an O--ring
as a secondary seal. If zero leak plug removal is neces-
sary, lightly rap the plug head using a punch and ham-
mer before using an allen wrench to remove the plug:
the impact will allow plug removal with less chance of
damage to the socket head of the plug.
25 ft- -lb
(33.9 N- -m)
20 ft- -lb
(27.1 N- -m)
1
3
20 ft- -lb
8
(27.1 N- -m)
6
25 ft- -lb
(33.9 N- -m)
9. Solenoid valve (port S5)
10. Solenoid coil (5 used)
11. Solenoid coil (5 used)
12. Nut
Groundsmaster 4500--D/4700--D
UP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4500-d3085730858