Toro Groundsmaster 4700-D Service Manual page 134

Hide thumbs Also See for Groundsmaster 4700-D:
Table of Contents

Advertisement

Deck Control Manifold Service (GM 4700- -D)
25 ft- -lb
(33.9 N- -m)
7
20 ft- -lb
(27.1 N- -m)
9
25 ft- -lb
(33.9 N- -m)
3
25 ft- -lb
(33.9 N- -m)
3
50 ft- -lb
4
(68 N- -m)
25 ft- -lb
(33.9 N- -m)
1. Manifold body
2. Nut (4 used)
3. Zero leak plug (#6)
4. Zero leak plug (#8)
NOTE: The ports on the manifold are marked for easy
identification of components (e.g. P1 is a gear pump
connection port and RV8 is the location for a relief
valve). See Hydraulic Schematics in Chapter 9 -- Fold-
out Drawings to identify the function of the hydraulic
lines and cartridge valves at each port location.
Hydraulic System
5 ft- -lb
(6.8 N- -m)
2
10
8
11
3
5. Zero leak plug (#4)
6. Proportional relief (PRV2 & PRV2)
7. Relief valve (RV8, RV9, RV10 & RV11)
8. Solenoid valve (SV1 & SV2)
25 ft- -lb
20 ft- -lb
(33.9 N- -m)
(27.1 N- -m)
6
7
10
6
1
UP
5
Figure 83
NOTE: The deck control manifold uses several zero
leak plugs. These plugs have a tapered sealing surface
on the plug head that is designed to resist vibration in-
duced plug loosening. The zero leak plugs also have an
O--ring as a secondary seal. If zero leak plug removal is
necessary, lightly rap the plug head using a punch and
hammer before using an allen wrench to remove the
plug: the impact will allow plug removal with less chance
of damage to the head of the plug.
Page 4 - - 100
25 ft- -lb
(33.9 N- -m)
5 ft- -lb
(6.8 N- -m)
2
7
20 ft- -lb
(27.1 N- -m)
10
9
(33.9 N- -m)
8
7
3
11
3
20 ft- -lb
(27.1 N- -m)
9. Logic valve (LC1, LC2, LC3 & LC4)
10. Solenoid coil (4 used)
11. Pilot piston (4 used)
Groundsmaster 4500--D/4700--D
25 ft- -lb
20 ft- -lb
(27.1 N- -m)
25 ft- -lb
(33.9 N- -m)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4500-d3085730858

Table of Contents