Toro Groundsmaster 4700-D Service Manual page 157

Hide thumbs Also See for Groundsmaster 4700-D:
Table of Contents

Advertisement

WARNING
If lift manifold is attached to machine, make sure
that cutting decks are fully lowered before loos-
ening hydraulic lines, cartridge valves or plugs
from lift manifold. If decks are raised as compo-
nents are loosened, decks may drop unexpect-
edly.
For solenoid and control valve service procedures, see
4WD/2WD Control Manifold Service in this section. Re-
fer to Figures 101 and 102 for cartridge valve and plug
installation torque.
IMPORTANT: A flow control orifice is placed be-
neath several of the hydraulic fittings on the lift con-
trol manifold (Fig. 102). The lift manifold uses two (2)
different orifice sizes. If a fitting is removed from the
lift control manifold and an orifice is in the manifold
port, make sure to remove orifice and label its posi-
tion for assembly purposes. Also note location of
groove in orifice for assembly purposes.
IMPORTANT: When installing orifice in manifold
(Fig. 102), make sure that orifice is flat in the base of
the manifold port. Manifold damage is possible if
the orifice is cocked in the cavity.
Groundsmaster 4500--D/4700--D
25 ft- -lb
(33.9 N- -m)
2
6
4
3
20 ft- -lb
3
(27.1 N- -m)
1. Manifold body
2. Straight fitting (3 used)
3. Zero leak plug (#4)
4. Orifice (0.063)
Page 4 - - 123
25 ft- -lb
7
20 ft- -lb
(33.9 N- -m)
(27.1 N- -m)
7
3
6
5
UP
Figure 102
5. Orifice (0.080)
6. O- -ring
7. O- -ring