F-19
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshoot-
ing assistance before you proceed. Call 1-888-935-3877.
TEST DESCRIPTION
This test will determine if the correct voltages are being:
a. applied to the primary of the T4 auxiliary transformer.
b. induced on the secondary windings of the T4 auxiliary transformer.
MATERIALS NEEDED
Volt/Ohmmeter (Multimeter)
Invertec STT Wiring Diagrams
Isolated 115VAC supply
5/16" Nut driver
7/16" Wrench
Note: Component locations and disassembly procedures may
TROUBLESHOOTING & REPAIR

T4 AUXILIARY TRANSFORMER TEST

WARNING
vary slightly on STT II models
INVERTEC STT
F-19