CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)
15. Place the machine on its side as shown in
Figure F.35. Slide the plastic retaining insu-
lators that go through the base of the
machine to one side. Pull the through-bolts
out of the machine, being careful to save all
the insulation and standoff material.
aside for reassembly.
TROUBLESHOOTING & REPAIR
FIGURE F.35 – REMOVING THROUGH-BOLTS
INVERTEC STT
PLASTIC RETAINING
INSULATORS
16. Remove the switch board and capacitor
assembly from the machine.