Lincoln Electric INVERTEC SVM129-B Service Manual page 45

Lincoln electric marine battery user manual
Table of Contents

Advertisement

F-7
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
No output. Main fuses are open,
indicating excessive current draw.
Machine loses output when gun
trigger is pulled or arc is struck.
Machine output returns after a few
seconds and trigger is pulled again.
The thermal indicator light is lit.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
1. With the input power removed,
inspect input leads for possible
shorts or grounds or miscon-
nections.
2. Install new fuses and reapply
power.
If fuses open again,
contact
your
Authorized
Facility.
1. The overcurrent sensor is acti-
vated, indicating that too much
output current is being drawn
from the machine.
welding current demands or
remove the "fault" in welding
cables.
2. Make sure that the gun tip is not
"shorted" to the work surface
and that the proper welding pro-
cedures are being used.
CAUTION
INVERTEC STT
detailed in the beginning of this manual.
RECOMMENDED
COURSE OF ACTION
1. Check the input power switch
(S1) and the reconnect switch
for "shorted" or "grounded"
wires or connections.
2. Perform the Input Rectifier
Test.
local
Lincoln
3. Perform the Switch Board
Field
Service
Test.
1. The current sensor may be
faulty.
2. The control PC board may be
Reduce
faulty.
F-7
Observe Safety Guidelines

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec sttInvertec stt ii

Table of Contents