TEST PROCEDURE
1. Turn off the Invertec STT and disconnect
main AC input power to the machine.
2. Using the 5/16" nut driver, remove the case
wraparound cover.
3. Perform
the
Discharge
procedure.
Maintenance section.
WARNING
ELECTRIC SHOCK can kill.
TROUBLESHOOTING & REPAIR
INPUT RECTIFIER TEST (continued)
FIGURE F.9 - INPUT RECTIFIER LOCATION
C
Input
Filter
Capacitor
See
the
• Before continuing with
the test procedure, per-
form the capacitor dis-
charge
procedure
to
avoid electric shock.
INVERTEC STT
INPUT
RECTIFIER
4. Locate the input rectifier. See Figure F.9.
5. Locate the leads needed to perform the
tests. See Figure F.9.
6. Use an ANALOG ohmmeter to perform the
tests shown in Table F.3.