F-16
T1 AUXILIARY TRANSFORMER TEST (continued)
8. If the correct secondary voltages are present
(according to Table F.1), the T1 transformer
is functioning properly.
9. If the secondary voltages are missing or
incorrect, the primary voltages must be
checked.
10. Remove input power to the STT machine.
11. Perform
the
Discharge Procedure.
12. Reconnect Plugs J30 & J31.
WARNING
ELECTRIC SHOCK can kill.
TEST POINTS
PLUG J30 PINS 1 TO 2
(LEADS 32 TO 33)
PLUG J31 PINS 1 TO 4
(LEADS 501 TO 504)
PLUG J31 PINS 2 TO 3
(LEADS 212 TO 503)
PLUG J31 PINS 2 TO 5
(LEADS 212 TO 43A)
PLUG J21 PINS 1 TO 4
(LEADS H1 TO H2)
PLUG J21 PINS 1 TO 2
(LEADS H1 TO H3)
PLUG J21 PINS 1 TO 3
(LEADS H1 TO H4)
PLUG J21 PINS 1 TO 6
(LEADS H1 TO H5) (H6)
NOTE: If the main AC input supply voltage varies, the auxiliary transformer voltages will vary by
the same percentages.
TROUBLESHOOTING & REPAIR
Input
Filter
Capacitor
• Before continuing with
the test procedure, per-
form the capacitor dis-
charge
procedure
to
avoid electric shock.
TABLE F.1 – T1 AUXILIARY TRANSFORMER VOLTAGES
INVERTEC STT
13. Gain access to the primary lead plug J21 by
removing the reconnect panel assembly
from the upper support panel using the 3/8"
wrench and slot head screwdriver. This will
allow the reconnect panel assembly to be
moved out of the way. Be careful NOT to
stress the leads connected to the reconnect
panel. See Figure F.2.
14. Before applying input power make certain
the reconnect panel assembly is insulated
and supported for safe operation.
NORMAL VOLTAGE
115VAC
18VAC
24VAC
42VAC
200/208VAC
220/230VAC
380/415VAC
440/460VAC
F-16