Lincoln Electric INVERTEC SVM129-B Service Manual page 9

Lincoln electric marine battery user manual
Table of Contents

Advertisement

A-3
TECHNICAL SPECIFICATIONS –Invertec STT II (For Codes 11115 AND 11116)
STANDARD VOLTAGE
200/208/3/50/60 HZ
200/208/380/400/415/3/50/60 HZ
DUTY CYCLE
60% Duty Cycle
100% Duty Cycle
CURRENT RANGE
Peak Current 0 - 450 Amps
Background
0 - 125 Amps
RECOMMENDED INPUT WIRE AND FUSE SIZES
I
NPUT VOLTAGE
FUSE(SUPER LAG)
AND FREQUENCY
OR BREAKER
200/50/60
208/50/60
380/50/60
400/50/60
415/50/60
HEIGHT
23.2 in
589 mm
1
115 VAC not present on European Models.
INSTALLATION
INPUT- THREE PHASE ONLY
RATED OUTPUT
AMPS
225
200
OUTPUT
OPEN CIRCUIT VOLTAGE
88 VDC Maximum
INPUT AMPERE
RATING ON
SIZE
NAMEPLATE
40
40
30
30
30
PHYSICAL DIMENSIONS
WIDTH
13.2 in.
336 mm
INVERTEC STT
INPUT CURRENT AT RATED OUTPUT
36/34
36/34/20/19/18
VOLTS AT RATED AMPS
AUXILIARY POWER
115
42
TYPE 75 C
COPPER
SUPPLY WIRE
IN CONDUIT
AWG (IEC) SIZES
36
34
10 (6 mm 2 )
20
19
18
DEPTH
24.4 in.
620 mm
A-3
29
28
1
VAC @ 4 Amps
VAC @ 4 Amps
TYPE 75 C
COPPER
GROUND WIRE
IN CONDUIT
AWG (IEC) SIZES
10 (6 mm 2 )
WEIGHT
100 lbs.
46 kg

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec sttInvertec stt ii

Table of Contents