5. Connect multimeter (ohms setting) leads to relay ter-
minals 30 and 87. Ground terminal 86 and apply +12
VDC to terminal 85. The relay should have continuity be-
tween terminals 30 and 87 as +12 VDC is applied to ter-
minal 85. The relay should not have continuity between
terminals 30 and 87 as +12 VDC is removed from termi-
nal 85.
Reelmaster 5010- H
6. When relay testing is complete, disconnect voltage
and multimeter leads from the relay terminals.
7. Replace relay if testing determines that it is faulty.
8. Secure relay to machine and connect machine wire
harness connector to relay. Install hood saddle to ma-
chine if it was removed. Lower and secure hood.