3. Fix the Mount Housing onto the Hanging
Mount (SBP-300HM) with 4 screws (M4xL16).
J
Note that the recommended torque for the screw
fastening is less than 3 kgf, to prevent
deformation of the mount housing.
4. Connect wires to the Terminal Block and attach it to the
bottom side of the camera.
(Refer to the "Camera Wiring Interface Board" at page 18.)
Set the communication protocol and ID DIP switches on the
bottom of the camera unit. (Refer to pages 21~23.)
5. Fix the camera to the Mount Housing by using 3 screws
removed in the step 2.
6. Attach the Dome Cover and turn it clockwise to fix.
Hanging
Mount
Mount Housing
English _35