Battery Operation Setting; Pa Vc (78V) Setting - JRC JSS-296 Service Manual

250w/500w/800w mf/hf radio equipment
Hide thumbs Also See for JSS-296:
Table of Contents

Advertisement

(f) Press ENT and turn the dial to "ORDINARY" voltage on the LCD.
CHG VOLT ADJUST
ORDINARY
(g) Adjust the Floating Charge Voltage by RV1.
(h) Turn the dial to "EQUAL" voltage on the LCD and adjust the Equal Charge Voltage by RV2.
CHG VOLT ADJUST
EQUAL
(i) Press ENT and turn off the "AC" switch.
(j) Re-assemble the unit.
4.2.3

Battery operation setting

If the Power Generator for emergencies is not equipped, set the battery using setting to SINGLE
(SES/HF) by the "BATT USE SET" menu.
Procedure
(a) Turn on the "AC" switch, pressing MENU .
(b) Press MENU and turn the dial to "BATT USE SET" menu on the LCD.
(c) Press ENT and set with the dial "DUAL (SES, HF)" or "SINGLE (SES/HF)" on the LCD.
BATT USE SET
SINGLE (SES/HF)
DUAL (SES, HF):
SINGLE (SES/HF): The Power Generator for emergencies is not equipped in ship.
(d) Press ENT and turn off the "AC" switch.
4.2.4

PA Vc (78V) setting

Since PA Vc (78V) is already adjusted at the time of factory shipments, it is not necessary to
Note
adjust it at the time of installation.
Procedure
(a) Turn off the "AC" and "DC" switches on the front panel.
48
26.2V
29.4V
The Power Generator for emergencies is equipped in ship.
SES and HF can be use simultaneously.
The Battery operation time is 1 hour or more.
SES and HF can't be use simultaneously.
The Battery operation time is 6 hours or more.
Dial
AC switch
CBG-2692
PS UNIT
TB19
80V +
RV3
TB20
80V -
80V ADJ
78.0v
Digital Volt
Meter
+
-