5.3.1.2 Ordinary self-diagnostic mode (level 1)

Menu items of the ordinary self-diagnostic mode are shown below.
Item
Self-diagnostic menu
1
Switch scan test
SWITCH SCAN
2
Motor clutch test
MOTOR&CLTCH
TEST
3
Test print
TEST PRINT
execution
4
Color registration
REG ADJUST TEST
correction test
5
Density correction
DENS ADJ TEST
test
6
Consumable item
CONSUMABLE
counter display
STATUS
7
Consumable item
PRINTER STATUS
accumulative
counter display
8
Factory/Shipping
FACTORY MODE
mode selection
SET
9
FUSE status
check
10
Engine parameter
SENSOR SETTING
setting
11
NVRAM parameter
NVRAM
setting
PARAMETER
44205401TH Rev.1
Maintenance
Adjustment contents
utilities
Entry sensor check and
No.18
switch check
Motor and clutch operation
No.19
test
PU built-in test pattern print
Operation
from the
maintenance
utilities cannot
be made.
Color registration mechanism
No.20
check
Density correction mechanism
No.21
check
Consumable items
No.23
consumption status display
Consumable items
No.23
accumulative consumption
status display
Switching between the
No.3, No.24
Factory mode and the
Shipping mode
Respective FUSEs status
No.24
display
Valid/Invalid setups of error
No.25
detection by various sensors
Do not use this item
Use of this
menu item is
prohibited
5.3.1.2.1 How to enter the self-diagnostic mode (level 1)
Note! For C711, password is required to enter the system maintenance menu
mode. Refer to Table 5-1 (C711)
1.
While pressing the MENU+ and MENU- keys simultaneously, turn on the power
to enter the system maintenance mode.
2.
Press the MENU+ key or MENU- key several times until the message "ENGINE
DIAG MODE" is displayed. Then, press the ENTER key to display "DIAGNOSTIC
MODE".
DIAGNOSTICMODE
XX.XX.XX
FACTORY/SHIPPING
3.
XXX.XX.XX of the message "DIAGNOSTIC MODE XX.XX.XX" that is displayed
on the LCD display area indicates the PU firmware version number. The
FACTORY WORKING MODE setup value is displayed in the right of the lower
row. S-MODE of "SHIPPING" is displayed normally.
4.
Press the MENU+ key or MENU- key to advance to the desired step of each
self-diagnostic menu. (The menu items rotate when either the MENU+ key or
MENU- key is pressed.)
5.3.1.2.2 How to exit the self-diagnostic mode
1. Turn off the power once and back on 10 seconds later.