Oki C711 Maintenance Manual page 104

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
4.
While the message "PRINT EXECUTE" that is set by the operation specified in
step 2 is being displayed, press the ENTER key and the test print is executed
with the setting value that has been set by steps 2 and 3.
Pressing the CANCEL key stops the test print.
If any alarm that is shown in the following details column is issued at startup of
test print or while test print is in progress, the test print is interrupted. (For error
details, refer to section 5.3.2.14 Panel display details. However, the comment to
be displayed is different in the case of the PU test print.)
Panel display
STACKER FULL
PAPER END
SELECTED TRAY
DUPLEX UNIT IS
NOT INSTALLED
SELECTED TRAY IS
NOT INSTALLED
REMOVE PAPER
OUT OF DUPLEX
INSTALL CASSETTE TRAY
OPEN
Print pattern (It cannot be used for checking PQ.)
0, 8 to 15....... White paper print
Pattern 1
44205401TH Rev.1
Details
Stacker full
No paper
DUPLEX is not installed
Selected tray is not installed.
DUPLEX internal error
Cassette removal
Pattern 2
Pattern 3
Pattern 5
Note! If the solid print (pattern 7) among
the local print function is selected
and printed with the setting of
100% each color, offset occurs. To
prevent print from this trouble, the
print setting of each color should
b e m a d e i n a c c o r d a n c e w i t h
the instruction specified in step
5.3.2.5-3 when performing the sold
print, and number of print colors
should be two colors or less.
Pattern 7
5. Maintenance Menu
Pattern 4
Pattern 6