Low Voltage Power Supply/Low Voltage Fan/ Hopping Motor/ Fuse Motor - Oki C711 Maintenance Manual

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
4.2.14 Low voltage power supply/Low voltage FAN/
Hopping motor/ Fuse motor
Warning
There is a risk of electric shock during replacement of the low voltage power
supply.
Use insulating gloves or avoid direct contact with any conducting part of the
power supply, and caution should be exercised during replacement.
The capacitor may take one minute to complete discharge after the AC cord
is unplugged. Also, there is a possibility that the capacitor doesn't discharge
because of a breakage of the PCB, etc., so remember the possibility of
electric shock to avoid electric shock.
(1) Take the cassette Assy out.
(2) Remove the control PCB. (See section 4.2.8)
(3) Remove all cables from Guide cable PowerLow.
(4) Remove the fuse I/F connector from low voltage power supply, disengage the
claws (2 places), and remove the Guide cable PowerLow
(5) Remove the two screws
CN2, CN3), and remove the low voltage power supply
At the same time, remove the screw
AC inlet Assy
.
(6) Disengage the claw C and remove the low voltage FAN
(7) Disengage the claw D (2 places) and claw E, and remove the motor cover
(8) Remove the four screws
fuse motor
out.
(9) Remove the three screws
ID motor
out.
Notes! • Be careful to install the low voltage FAN
• Please confirm the setting of AC input voltage when installing the low
voltage power supply
100V: the short plug is mounted to the connector CN6
230V: the short plug is not mounted to the connector CN6
• Low-voltage power supply
together. (The pair of low-voltage power supply and AC Inlet Assy
meets the safety standards.)
44205401TH Rev.1
Risk of Electric Shock
.
(silver, No:42920406) and four connectors (CN1,
.
(black, No:42932708) and remove the
.
(silver, No:42920406) and connector, and take the
(silver, No:42920406) and connector, and take the
in the proper direction.
.
and AC Inlet Assy
should be replaced
Claw D
Air
.
PRN PCB
POWER connector
CN3
Note! CN6: A connector used to switch the AC input voltage setting
100V short plug is mounted/ 230V short plug is not mounted.
4. Component replacement
Claw E
Low-voltage power supply
For CN6
Fuser I/F connector
Short plug
CN2
CN6
CN1
AC switch
73 /

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mps711c

Table of Contents