PILOT CONTROL SHUT-OFF LEVER

Pilot control shut-off lever (1) functions to prevent
misoperation of the machine from occurring if the control
levers are accidentally moved when leaving the operator's seat
or when entering the cab.
d
WARNING:
• Always pull pilot control shut-off lever (1) into
the full LOCK position. The pilot control shut-off
function will not be activated otherwise.
• When leaving the machine:
• Stop the engine.
• Then, pull pilot control shut-off lever (1) up to the
LOCK position.
• Always check to be sure that pilot control shut-off
lever (1) is pulled up to the LOCK position before:
• Transporting the machine.
• Leaving the machine at the end of the shift.
Pilot Control Shut-Off Lever Operation
Before Leaving the Machine:
1. Park the machine on a firm, level surface. Lower the
bucket to the ground. Return all control levers to neutral.
Properly shut down the engine.
2. Pull pilot control shut-off lever (1) up into the full LOCK
position.
Before Starting Operation:
1. Confirm that pilot control shut-off lever (1) is pulled up to
the LOCK position.
After starting the engine:
1. Confirm that all control levers and pedals are in neutral
and that no part of the machine is in motion.
2. Lower pilot control shut-off lever (1) to the UNLOCK
position.
If any part of the machine (any actuator) moves when pilot
control shut-off lever (1) is lowered to the UNLOCK position
despite the fact that all controls are placed in neutral, the
machine is malfuntioning. Immediately pull pilot control
shut-off lever (1) back to the LOCK position, and stop the
engine. Then, see your authorized dealer.
OPERATING THE MACHINE
5-7
LOCK Position
1
UNLOCK Position
1
M1U1-01-025
M1U1-01-024