CONTENTS OF ALARMS

Display
Overheat Alarm
M178-01-036
Engine Warning Alarm
M183-01-080
Engine Oil Pressure Alarm
M178-01-037
Alternator Alarm
M183-01-071
Fuel Level Alarm
M178-01-034
Auto-Lubrication Alarm
T1J1-05-01-005
Air Filter Restriction Alarm
M183-01-067
Fuel Filter Restriction Alarm
M1U1-01-116
Work Mode Alarm
T1V1-05-01-102
Pilot Control Shut-Off Lever
Alarm
T1V1-05-01-103
f
NOTE: H: When the fuel level alarm lights while operating the machine on a level surface, approximately 90 liters of fuel
remain.
OPERATOR'S STATION
Contents of Alarms
Engine coolant temperature is above normal.
Stop operation. Run the engine at low idle to lower the coolant
temperature.
Engine or engine related parts are abnormal.
Consult your nearest Hitachi dealer.
Engine oil pressure is low.
Immediately stop engine.
Check engine oil system and oil level.
Check electrical system.
Check alternator and battery system.
Fuel level is low. Refill fuel as soon as possible.H
Check Auto-Lubrication circuit.
Charge grease can or check grease lines.
Air filter elements are clogged.
Clean or replace air filter elements.
Fuel filter is clogged.
Clean or replace fuel filter.
Check Work Mode system.
See your nearest authorized dealer.
Check pilot control shut-off lever system.
See your nearest authorized dealer.