10.4

Disable interlocking output (C4)

Not available for users with access level / type "Information only".
Up to 100 Interlocking outputs (Type = Interlocking) can be
individually disabled via this menu (C4) but not via menu H2.
All interlocking outputs can be collectively disabled via menu H2/B4.
Disabled interlocking outputs are listed in menu H4/U1. The LED
"Disablements" (L8) is also indicating one or more disabled
interlocking outputs.
Log in with a User name and Password for typ Building officer (or
Service personnel), see page 5.
H1 Perform monthly test
Scroll (or press "9") to menu H9.
H9 Interlocking outputs and inputs
Press "A" to sub menu C1.
C1 Activated interlocking outputs / inputs
Scroll (or press "4") to menu C4.
C4 Disable interlocking output
Press "A". Use the keypad to specify Area – Point (AA and PP) for
the interlocking output to be disabled.
Press "A". Interlocking output AA-PP disabled.
Press "A". If more interlocking outputs shall be activated do as
above, if not press "Return" to menu C4.
Scroll to another menu or press "Return" to menu H9. Scroll to
another menu or leave the menu system by pressing "Return".
EBL128 version 2.0.x, Daily user's manual