(2) Adjustment of in-bin paper detecting sensor
1
2
FA-S620
ON
1
2
3
4
FA-S660
ON
1
2
3
4
3
4
5
3-12
Remove all the paper from the bin unit.
Remove the right cover and set the dip switch
on the sorter controller PCB as shown.
(SW3: FA-S620, SW1:FA-S660)
5
6
5
6
Press the manual staple key.
Check the lighting condition of the manual
staple key.
Kept ON: Adjustment completed.
Blinking: Improper adjustment.
Turn OFF all the dip switch
(SW3: FA-S620, SW1:FA-S660)
• Turn OFF and ON the power
switch of the copier.
Check the installation condition
of the sensor and repeat the
procedure of step 3.